摘要
人因可靠性分析 (HRA)已成为概率安全分析 (PSA)必不可少的内容 ,事故前人因事件可靠性分析对有效预防维修、调校工作中的人因失误有着重要作用 ,是人因可靠性分析的重要组成部分 ,对PSA最终计算结果有重要影响。笔者结合核电站人因可靠性分析的实际需求 ,运用了以THERP为主的人因失误概率评价方法 ,创建了事故前人因事件分析的基本程序、方法及分析文档模式 ,表述了程序化的事故前人因事件分析模式 ,为我国核电站事故前人因可靠性分析提供了完整和有效的分析方法 ,并有效用于秦山核电站的PSA。
Human reliability analysis (HRA) has been a necessary part of probability safety analysis (PSA). Pre initiators HRA plays an important role in effectively preventing human errors in maintaining and adjusting work and has great effect on the final result of PSA. It is an important part of HRA. The essay expounds a basic procedure, technique and analysis document mode on the basis of combining with the factual requirements in HRA and using human errors probability appraisal technique taking THERP as its main component. It expresses a formulated pre initiators HRA mode and provides a complete and effective technique to the pre initiators HRA in our country's nuclear power plant. It has been effectively applied in the PSA of Qinshan Nuclear Plant.
出处
《中国安全科学学报》
CAS
CSCD
2003年第2期50-53,共4页
China Safety Science Journal
基金
国家自然科学基金项目 (70 2 710 16)
国防军工研究项目(Z0 12 0 0 2A0 0 1)
秦山核电站资助项目