基于多参考点的X线双能量减影算法 被引量:5

A X-ray Dual-energy Image Subtraction Method Based on Multi-referential Points
暂未订购
导出
摘要 提出了不直接依赖于入射X线强度的基于多参考点的双能量减影算法 .该算法选取图像中的若干个像素点作为参考点 ,在对这些参考点进行平滑处理后分别求解双能量方程以产生多幅具有相同纹理的减影图像 ,将这些图像进行平均后得到保留着动态信息的骨骼和软组织图像 .该算法将减影和滤波过程同时进行 ,提高了结果图像的质量 .实验表明该算法具有较强的稳定性 ,实现了计算机自动处理 . A novel X-ray dual-energy image subtraction method based on the multi-referential points is proposed. For this method, it's no need to evaluate the initial intensity of the incoming X-ray. The method firstly selects several pixels in the original image as the referential points and smoothes them. Then the smoothed referential points are applied to solve the dual-energy equations individually and make the subtracted images that have the same texture. The result image, which produced by the average of those subtracted images, keeps the entire dynamic information of soft tissue and bone. This method can improve the quality of the subtracted image for the subtraction processing and the filter working together. The experiment shows that the method is robust and can be implemented by the computer automatically.
出处 《光子学报》 EI CAS CSCD 北大核心 2003年第2期187-191,共5页 Acta Photonica Sinica
基金 国家九五重点科技项目 (攻关 )滚动计划 (96 92 0 12 0 1) 国家自然科学基金(396 310 2 0 )资助项目
关键词 X射线 双能量减影 图像处理 X-ray Dual-energy image subtraction Image processing
  • 相关文献

参考文献6

  • 1[1]Theodorou D J,Theodorou S J. Dual-energy X-ray absorptiometry in clinical practice: Application and in terpretation of scans beyond the numbers. Clinical Imaging, 2002, 26(1): 43~49
  • 2[2]Shaw C C. Gur D. Comparison of three different techniques for dual-energy subtraction imaging in digital radiograph: A signal-to-noise analysis. Journal of Digital Imaging, 1992, 15(4): 262~270
  • 3[3]Kalender W A, Klotz E,Kostari dou L.An algorithm for noise suppression in dual energy CT material density images.IEEE Trans on Medical Imaging,1988,7(3):218~224
  • 4[4]Kido S, Ikezoe J. Clinical evaluation of pulmonary nodules with single-exposure dual-energy subtraction chest radiography with an iterative noise-reduction algorithm . Radiology,1995,194(2): 407~412
  • 5[5]Genton L, Hans D, Ursula G, et al. Dual-energy X-ray absorptiometry and body composition: differences between devices and comparison with reference methods . Nutrition,2002,18(1): 66~70
  • 6[6]Chuang K S , Huang H K. A fast dual-energy computational method using isotransmission lines and table look up. Med Phys,1987.14(2):186~192

同被引文献20

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部