摘要
本文研究了用氨气敏电极 -标准加入法测定土壤脲酶活性的新方法。该法使样品液和标准溶液均处于同一条件下测定 ,消除了土壤中基体对测定的影响 ,提高了方法的准确性。方法简便、快速 ,结果可靠 ,应用于不同土壤样品中脲酶活性的测定 ,相对标准偏差为 1 .78%~ 3 .94% ,回收率在 98.3 %~ 1 0 1 .
Standard addition method was proposed for the ammonia gas sensor determination of urease activity in the soil The errors due to the soil elimmated and the accuracy of the determination was improved The advantage of this method was simple operating, rapid and reliable.This method had been applied to the determination of urease activity in different soil samples,the relative standard deviations were 1 78%~3 94%, the recoveries were 96 2%~101 8%.
出处
《广西农业生物科学》
CAS
CSCD
2003年第1期50-53,共4页
Journal of Guangxi Agricultural and Biological Science
基金
国家"九五"科技攻关专题资助项目 ( 960 0 70 40 6)
关键词
氨气敏电极
标准加入法
土壤
脲酶活性
ammonia gas sensor
standard addition method
soil