摘要
针对目前无功补偿装置中采用的单相过零投切方法存在的缺点 ,本文提出采用模糊控制的方法。并对模糊控制技术在低压电网综合补偿系统中的应用进行了详细的介绍 ,仿真与实际应用表明 。
In order to overcome the disadvantage of the single phase passing zero control in the reactive power compensation device, fuzzy control is put forward in this paper. Fuzzy control technology applied to low voltage power integrated compensation system is introduced in detail. Simulation and practical operation show that the reactive power and the three phase imbalance can be compensated well at the same time with the fuzzy control method.
出处
《电力电容器》
2003年第1期6-9,共4页
Power Capacitors
基金
国家自然科学基金( 69772 0 0 7)资助项目