摘要 由HVDC线路的离子流场数学模型,严格地从理论上导出实际HVDC线路离子流场与比例模型线路离子流场间的关系,同时还导出为预测实际HVDC线路离子流场建立的模型线路应满足的必要条件。采用数值计算法对实际HVDC线路和比例模型线路的离子流场分别进行了计算,结果表明两者确实很好地服从导出的上述关系。 Based on the commonly used mathematical model of the ion flow field of HVDC lines, the relationship between the ion flow field of actual HVDC lines and that of scaled model lines has been derived theoretically. The necessary condition that the scaled model lines has to be satisfied to has also been obtained. The numerical method is used to calculate the ion flow field under actual HVDC lines and under scaled model lines respectively. It is shown that the ion flow fields of both lines accord with the derived relationship very well indeed.
作者 周浩 张守义
机构地区 浙江大学电机系
出处 《高电压技术》 EI CAS CSCD 北大核心 1992年第2期19-23,共5页 High Voltage Engineering
关键词 HVDC 离子流场 比例模型 输电线路 HVDC ion flow field scaled model
  • 相关文献

参考文献2

共引文献2

同被引文献23

  • 1郑正圻,成梦兰.高压直流绝缘子串电压分布计算[J].高电压技术,1994,20(1):60-64. 被引量:20
  • 2侯远航,邬雄,万保权,张广州,孙竹森,吴巾克.±500 kV直流线路极导线垂直排列的合成场强[J].高电压技术,2005,31(5):37-38. 被引量:16
  • 3河野照哉 宅间董[日].电场数值计算法[M].北京:高等教育出版社,1985..
  • 4Qin Bailin, Sheng Jianni, Yah Zhang, et al. Accurate calculation of ion flow field under HVDC bipolar transmission lines[J]. IEEE Trans on PWRD, 1988,3(1) : 368-376.
  • 5Janisehewskyj W, Gela G. Finite element solution for electric fields of coronating DC transmission lines[J]. IEEE Trans on PAS. 1979,98(3) :1000-1012.
  • 6Aboelsaad M M. Shafai L, Rashwan M. Numerical assessment of unipolar corona ionised field quantities using the finite-element method[J]. IEE Proceedings, Part A: Physical Science, Measurement and Instrumentation, Management and Education, Reviews, 1989,136(2):79-86.
  • 7Takuma T, Ikeda T, Kawamoto T. Calculations of ion flow fields of HVDC transmission lines by the finite element method[J]. IEEE Transon PAS, 1981,100(12) :4802-4810.
  • 8Li Xin, Raghuveer M R, Cirie I R A new method for solving ionized fields associated with HVDC transmission lines [C]. Conference on Electrical Insulation and Dielectric Phenomena. Virginia Beach, Virginia,USA, 1995: 455-458.
  • 9Yu M, Kuffel F. A new algorithm for evaluating the fields associated with HVDC power transmission lines in the presence of corona and strong wind[J]. IEEE Trans on Magnetics, 1993,29(2) : 1985-1988.
  • 10Abdel-Salam M, Al-Hamouz Z. Analysis of monopolar ionized field as influenced by ion diffusion[J]. IEEE Trans on IA, 1995,31(3):484-493.

引证文献2

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部