期刊文献+

水溶液中丙酮的敏化室温磷光测定 被引量:1

Determination of Acetone by Sensitized Room Temperature Phosphorimetry in Solution
在线阅读 下载PDF
导出
摘要 测定水溶液中微量丙酮,常用吸光光度法和色谱法等,这些方法固然灵敏度较高,但样品的预处理比较复杂,分析速度慢,线性范围窄.本文以丁二酮为能量受体,建立了水溶液中微量丙酮的敏化室温磷光测定法.方法简便快速,重现性好,灵敏度亦高. A sensitized room temperature/phosphorimetric method by using biacetyl as an energy acceptor for the determination of acetone in solution was developed. Acetone was excited at 274 nm and the phosphorescence intensity emitted from biacetyl was measured at 515 nm. The factors affecting the stability of the sensitized phosphorescence at room temperature in solution were investigated and discussed. A simple and effective unit which can be operated on the cell holder for the deoxygenation of the solution with N2 gas was also designed. The calibration curve was linear over the concentration range of 2. 0×10-4-1. 5×10-2 mol/L(r=0. 999) and the limit of detection was 8. 0×10-5 mol/L.
机构地区 厦门大学化学系
出处 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 1992年第5期590-592,共3页 Chemical Journal of Chinese Universities
关键词 丙酮 丁二酮 敏化磷光 测定 Acetone, Biacetyl, Sensitized room temperature phosphorimetry