摘要
分析了换流变压器和平波电抗器主绝缘的特点,论述了直流设备与交流设备绝缘结构的主要差别,以及影响换流变压器和平波电抗器主绝缘安全和可靠性的主要因素。
This article analyzes the characterstic of m aj or insulation of the converter transformer and smoothing reactor.It expounds t he main differences of the insulation structures between DC and AC equipment,and the main factors influencing on the safety and reliability of main insulati on of converter transformer and smoothing reactor.
出处
《高压电器》
CAS
CSCD
北大核心
2003年第1期7-7,15,共2页
High Voltage Apparatus