期刊文献+

流动注射-速差动力学分析研究meso-四(3-氯-4-磺基苯)卟啉光度法同时测定铜锌 被引量:5

Simultaneous Determination of Copper and Zinc with meso-Tetrakis (3-Cl-4-Sulfophenyl) porphyrin by Flow Injection-Differential Kinetic Method
在线阅读 下载PDF
导出
摘要 本文研究了多种金属离子与meso-四(3-氯-4-磺基苯)卟啉的显色反应动力学特性。利用Cu(Ⅱ)、Zn(Ⅱ)与其它金属离子之间反应速率上的差异,建立了一种选择性同时测定Cu(Ⅱ)、Zn(Ⅱ)的流动注射分析法,不经分离同时测定桃叶样品中的铜、锌,结果满意。 The Kinetic characteristics of the reaction of Cu (Ⅱ),Zn(Ⅱ),Mn(Ⅱ),Cd(Ⅱ),Pd(Ⅱ),Hg(Ⅱ),Ni (Ⅱ),Co(Ⅱ),Pb(Ⅱ),Fe(Ⅲ)and Pt(Ⅳ) with meso tetrakis (3- Cl- 4- sulfophenyl) porphyrin and the influence of other metal ions on the reaction of Cu(Ⅱ) and Zn (Ⅱ) have been studied. On the basis of the different formation rates of metalloporphyrins, a new method for the simultaneous spectrophotometric determination of trace amounts of Cu (Ⅱ) and Zn (Ⅱ) using merging zone FIA technigue has been developed. It is much more selective than conventional porphyrin spectrophotometric methods. The relative standard deviation of Cu and Zn are 2. 69% and 0. 98% respectively.
机构地区 武汉大学化学系
出处 《分析试验室》 CAS CSCD 北大核心 1992年第2期19-21,共3页 Chinese Journal of Analysis Laboratory
关键词 卟啉 分光光度法 FIA Flow injection analysis Porphyrin Spectrophotometry Copper and zinc determination