期刊文献+

流动注射荧光法同时测定强力霉素和维生素B_2 被引量:8

Simultaneous Determination of Doxycycline and Vitamin B_2 by Flow Injection Fluorimetric Method
暂未订购
导出
摘要 本文提出了流动注射络合荧光法同时测定微量强力霉素和维生素B_2新方法。在中性条件下,维生素B_2在汞灯激发下于520hm发射荧光,而强力霉素与0.10mol/L MgSO_4溶液快速反应生成的荧光络合物也在520nm发射荧光,它们的荧光强度在维生素B_2和强力霉素浓度比为10∶1~1∶25范围内有加合性,由此同时测定了混合物中的维生素B_2和强力霉素。本法测定尿液中维生素B_2和强力霉素的回收率为95%~102%。 A new flow injection fluorimetric method for the simultaneous determination of doxycycline and vitamin B_2 is proposed. In neutral solution, vitamin B_2 emits fluorescence at 520nm when excited by Hg lamp, and doxycycline reacts with 0.10mol/L MgSO_4 to form fluorescence complex which emits fluorescence at 520nm. Their fluorescence intensities are of additive property in the doxycycline and vitamin B_2 concentrations ratios of 10:1~1:25, which has been used for the determinaton of doxycycline and vitamin B_2 in combina- tion. The recoveries of doxycycline and vitamin B_2 in urine are in the range of 95%~120%.
机构地区 厦门大学化学系
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1992年第11期1261-1264,共4页 Chinese Journal of Analytical Chemistry
关键词 流动注射 荧光法 强力霉素 维生素B Flow injection Doxycycline Vitamin B_2