期刊文献+

西安脉冲堆计算值和实测结果分析 被引量:1

Analysis of Results for Calculated Values and Experimental Data of Xi'an Pulsed Reactor
在线阅读 下载PDF
导出
摘要 介绍了西安脉冲堆堆芯布置、计算模型和程序以及计算值与实验测量结果分析。西安脉冲堆在满功率(2MW)下连续运行了72小时,证明西安脉冲堆整个系统和设备是良好的、安全可靠的。根据西安脉冲堆计算值与测量值的比较,证明计算程序可靠,具有较高精度。西安脉冲堆理论计算值与实验测量值符合较好,完全满足工程设计要求,实验测量结果达到了设计指标的要求。 The core configuration of Xi'an pulsed reactor, model and program of calculation as well as analysis of the calculated values and experimental data are presented. Xi'an pulsed reactor in full power (2 MW)had been operated for 72 hours, which verified that integral system and device are safe and reliable. Comparing calculated values with experimental data, the reliability and precision of calculation program are confirmed. The calculated values and experimental data meet well to requirement of project, and the experimental results reach match with design target.
出处 《核动力工程》 EI CAS CSCD 北大核心 2002年第6期8-11,共4页 Nuclear Power Engineering
关键词 西安脉冲堆 计算值 临界棒位 积分价值 次临界度 部件反应性 实验测量结果 Calculations Control rods Criticality (nuclear fission) Experiments Reactor cores Reliability
  • 相关文献

参考文献1

共引文献11

同被引文献7

  • 1章宗耀,李大图,姚栋,程和平,谢仲生,尹邦华.轻水堆燃料组件计算程序包TPFAP[J].核动力工程,1993,14(2):117-121. 被引量:14
  • 2姚栋,李大图.三维堆芯中子扩散细网格有限差分临界-燃耗计算程序研制[C].2006年反应堆物理会议论文集,哈尔滨工程大学,2006,7.
  • 3姚栋,曾道桂,刘静波.群常数TPLIB-95的宏观验证[R].中国核科技报告,CNIC-01065/SINRE-0063,1996.5.
  • 4Francisco Leszczynski,Daniel Lopez Aldama.WIMS-D Library Update[M].1AEA-DOC-DRAFT.
  • 5Brifford J,Pellerin P,Brushwood J M,et al.The Feasibility of Using a 15MW General Atomics TRlGA Core as an Autonomous Marine Power Supply[C].Proceedings of the 2003 International Congress on Advances in Nuclear Power Plants(ICAPP'03),Cordoba,(2003).
  • 6章宗耀,程和平.铀氢锆堆物理计算模型与程序[J].核动力工程,1989,10(1):52-57. 被引量:12
  • 7何绍群,黄礼渊,付正中,邓圣,贺笛,蒙汇兵,黄文楼.西安脉冲堆带核调试试验[J].核动力工程,2002,23(6):69-73. 被引量:5