摘要
通过比较《自动喷水灭火系统设计规范》(GB50084-2001)与原有国家规范《自动喷水灭火系 统设计规范》(GBJ84-85),结合工程实际,对规范中关于自动喷水灭火系统设计的水力计算、喷头布置、 供水等重要修订进行了分析思考。
A comparison is made between the Code of design far sprinkler systems(GB50084-2001)and the Code of design for sprinkler systems(GBJ84-85). In respect to the engineering practice, theoretical analysis is made in this paper to som of the important amendments on hydraulic calculation, sprinkler disposal and water supply in the new Code of Design for Sprinkler Systems.
出处
《连云港化工高等专科学校学报》
2002年第4期37-40,共4页
Journal of Lianyungang College of Chemical Technology