摘要
针对靶板不规则破孔孔径难以准确测量的技术难题,文中提出一种采用流量比对法的测量设备方案。该方案将不规则破孔等效为规则孔进行孔径大小准确测量,具有贴近实际工况、简单易实施、工作可靠以及使用成本较低等显著优势,对水下毁伤效能评估具有特殊表征意义。其核心原理亦可为其他行业解决类似不规则孔径测量需求提供重要参考。
Aiming at the technical problems of accurately measuring the aperture of irregular broken holes on target plates,this paper proposed a measurement device scheme based on the flow comparison method.The scheme equated irregular broken holes to regular holes for aperture characterization,which was close to the actual working condition,and it was simple and easy to implement,reliable,and low-cost.It has special characterization significance for underwater damage effectiveness evaluation.The core principle can also provide important reference for other industries to address similar irregular aperture measurement requirements.
作者
张建亭
姜晓鹏
曲春亮
张稀桐
许波
ZHANG Jianting;JIANG Xiaopeng;QU Chunliang;ZHANG Xitong;XU Bo(The 705 Research Institute,China Shipbuilding Industry Corporation Limited,Xi’an 710077,China;92417th Unit,the Liberation Army of China,Fuding 355200,China)
出处
《水下无人系统学报》
2025年第6期1091-1096,1110,共7页
Journal of Unmanned Undersea Systems
关键词
靶板
破孔
孔径测量
流量比对法
target plate
broken hole
aperture measurement
flow comparison method