摘要 对深圳市高密度老旧住宅疏散空间进行调研,分析室内疏散廊道、疏散楼梯等典型疏散区域设计难点,选取深圳南油小区B区高密度老旧住宅为例,i i以提升火灾疏散效率为目标,选择烟气模拟软件Pyrosm和人员疏散软件Pathfnder,分别对疏散廊道和疏散楼梯构建烟气蔓延场景和人员疏散场景,通过改变廊道宽度、廊道端头放大面积、楼梯宽度和楼梯数量等设计方式,进行对比模拟实验,分析不同设计方式对人员疏散的影响机制,提出高密度老旧住宅廊道和疏散楼梯的空间优化策略。 This study investigates the evacuation space of high-density old residential buildings in Shenzhen,and analyzes the difficulties in evacuation design for typical evacuation areas such as indoor evacuation corridors and stairs.Taking high-density old residential buildings in the B district of Nanyou Life in Shenzhen as an example,the goal is to improve the evacuation efficiency of high-density old residential fires.Pyrosim smoke simulation software and pathfinder personnel evacuation software are selected.Construct smoke spread scenarios and personnel evacuation scenarios for evacuation corridors and evacuation staircases,and conduct comparative simulation experiments by changing corridor width,enlarged area at corridor ends,staircase width,and number of staircases.Analyze the impact mechanism of different design methods on personnel evacuation,and propose spatial optimization strategies for high-density old residential corridors and evacuation staircases that are conducive to improving personnel evacuation efficiency.Provide a reference for improving the safety design and renovation path of such buildings.
作者 张彤彤 田靓 李佳璐 肖靖 ZHANG Tongtong;TIAN Liang;LI Jialu;XIAO Jing
出处 《建筑学报》 北大核心 2025年第S1期173-179,共7页 Architectural Journal
基金 教育部人文社科基金项目(24YJC630300) 国家重点研发计划项目(2023YFC3807402-4) 广东省哲学社会科学规划项目(GD23CYS05)
关键词 高密度 老旧住宅 空间优化 安全疏散 high density old residential buildings spatial optimization safe evacuation
  • 相关文献

参考文献7

二级参考文献44

  • 1袁家冬,孙振杰,张娜,赵哲.基于“日常生活圈”的我国城市地域系统的重建[J].地理科学,2005,25(1):17-22. 被引量:88
  • 2张青松,刘茂,赵国敏.改进的疏散时间计算模型在奥运赛场中的应用[J].中国工程科学,2007,9(4):64-69. 被引量:10
  • 3Bukowski B W. Fire Hazard analysis[A]. SFPE Handbook of Fire Protection Engineering[M]. Chapter 7 - 11. 2nd Edition. Society of Fire Protection Engineers and National Fire Protection Association, Boston, USA, 1995.
  • 4Babrauskas V. Burning rate[A]. SFPE Handbook of Fire Protection Engineering[M]. Chapter 1 - 3,2nd Edition. Society of Fire Protection Engineers and National Fire Protection Association, Boston, USA, 1995.
  • 5Cooper L Y, Stroup W D. ASET - A computer program for calculating available safety egress time[J]. Fire Safety Journal, 1985,9:29 -45.
  • 6SFPE. The SFPE engineering guide to performance - based fire protection analysis and design [R]. Draft for Comments. Society of Fire Protection Engineers, Bethesda, MD,2000.
  • 7David D. Evans,David W. Stroup. Methods to calculate the response time of heat and smoke detectors installed below large unobstructed ceilings[J] 1986,Fire Technology(1):54~65
  • 8B. J. McCaffrey,J. G. Quintiere,M. F. Harkleroad. Estimating room temperatures and the likelihood of flashover using fire test data correlations[J] 1981,Fire Technology(2):98~119
  • 9朱壹松,王德,马力.基于生活圈的城乡公共服务设旌配置研究-以仙桃为例[C]//规划创新——2010中国城市规划年会,2010.
  • 10朱家瑾.居住区规划设计[M],2版.北京:中国建筑工业出版社,2007:103.

共引文献173

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部