本文通过对模拟显示式测量仪器在不同计量方法下的量值修正法进行分析研究,并基于GB/T8 170-2008《数值修约规则与极限数值的表示和判定》,对该类仪器为满足检定/校准结果符合仪表“可读性”原则的修约处理方法进行总结,从而更加准确地表述量值。
This article analyzes and studies the value correction methods of analog display measuring instruments under different measurement methods,and based on GB/T 8170-2008"Numerical rounding rules and representation and determination of limit values",summarizes the rounding processing methods for this type of instrument to meet the principle of"readability"of the calibration/verification results,so as to more accurately describe the values.