近年来,沉浸式夜游项目快速发展,相关场景下的应急照明却未得到足够重视。文章以普者黑景区夜游项目为例,提出一种通过UPS不间断电源与功能照明整合的应急照明系统优化方案。方案通过分析夜游项目在不同夜游场景及运营时段差异化照明需求,结合配电系统二次回路设计,实现了应急照明与功能照明的功能整合。
In recent years,immersive night tour projects have developed rapidly,but emergency lighting in related scenarios has not received enough attention.Taking the night tour project of Puzhehei Scenic Area as an example,this paper proposes an optimization scheme for emergency lighting system through the integration of UPS uninterruptible power supply and functional lighting.By analyzing the differentiated lighting needs of the night tour project in different night tour scenarios and operation periods,the solution realizes the functional integration of emergency lighting and functional lighting in combination with the secondary circuit design of the power distribution system.