摘要
高铁站内目前采用一体化轨道电路,既要实现可靠的占用检查,又要实现发码功能,在日常维护过程中对机车最小信号电流测试尤为重要。通过对入口电流和最小机车信号电流进行分析,明确站内一体化区段最小机车信号电流测试位置和测试方法,便于日常测试和维护。
At present,integrated track circuits are used in high-speed railway stations to achieve both reliable occupancy inspection and code sending function.It is particularly important to test the minimum signal current of the locomotive during daily maintenance.This paper analyzes the inlet current and minimum locomotive signal current to clarify the testing location and method for the minimum locomotive signal current in the integrated section of the station,which is convenient for daily testing and maintenance.
出处
《铁路通信信号工程技术》
2024年第S1期1-4,共4页
Railway Signalling & Communication Engineering
关键词
一体化轨道电路
最小机车信号电流
入口电流
integrated track circuit
minimum locomotive signal current
inlet current