摘要
以深圳地铁7号线笋岗站为例,对结构复杂的地下3层叠线侧式车站给排水及水消防设计进行探讨,详述各系统设计参数选取及计算过程,分析管网、设备组成,总结设计过程的重难点。
Taking Shenzhen Metro Line 7 Sungang Station as an example,this paper discusses the design of water supply and drainage and waterfire protection for a complex underground three-layer stacked side station,describes the selection and calculation process of each system design parameters,analyzes the pipe network and equipment composition,summarizes the key points and difficulties in the design process.
作者
樊波
黄千超
王哲
何湖滨
FAN Bo;HUANG Qian-chao;WANG Zhe;HE Hu-bin(Zhejiang Digital Intelligent Transportation Institute Technology Co.Ltd.,Hangzhou 310000,China)
出处
《工程建设与设计》
2025年第11期37-39,共3页
Construction & Design for Engineering
关键词
地铁车站
叠线侧式站台
给排水系统
水消防系统
metro station
stack-up side platform
water supply and drainage system
waterfire-fighting system