期刊文献+

二氧化镎中微量铀激光荧光法测定不确定度评定

Evaluation of Uncertainty for Determination of Trace Uranium in Neptunium Dioxide by Laser Fluorescence
在线阅读 下载PDF
导出
摘要 针对激光荧光法测定二氧化镎中微量铀过程中各因素对测定结果的影响,根据产生不确定度分量的性质,通过A类和B类不确定度评定,对各不确定度分量进行了分析和量化,获得了测定方法的合成标准不确定度及扩展不确定度,即二氧化镎中微量铀测定结果的扩展不确定度为66μg/g(K=2)。 In view of the influence of various factors on the determination results of trace uranium in neptunium dioxide by laser fluorescence method,the uncertainty components were analyzed and quantified through Class A and Class B uncertainty evaluation,and the synthetic standard uncertainty and extended uncertainty of the determination method were obtained.That is,the extended uncertainty for the determination of trace uranium in neptunium dioxide is 66μg/g(K=2).
作者 孙媛媛 何龙 孔令芳 杨利 SUN Yuan-yuan;HE Long;KONG Ling-fang;YANG Li(CNNC 404 Co.,Ltd.Lanzhou 732850,China)
出处 《全面腐蚀控制》 2025年第4期189-191,198,共4页 Total Corrosion Control
关键词 二氧化镎 微量铀 不确定度 neptunium dioxide trace amount of uranium uncertainty
  • 相关文献

参考文献3

二级参考文献14

共引文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部