摘要
红外整机成像时需要对红外探测器的输出进行非均匀校正,来获得相对均匀可观的图像。在一款碲镉汞长波红外探测器整机成像实验时,图像出现了“暗环”现象,通过分析确认了“暗环”现象的机理,并通过优化改进,消除了成像“暗环”,为其他长波红外探测器成像应用提供了借鉴。
Infrared imaging requires non-uniform correction of the output of the infrared detector to obtain a relatively uniform and impressive image.The dark ring phenomenon occurs during the imaging process of long-wave infrared HgCdTe detector systems,and the mechanism is confirmed through analysis,and the imaging dark ring is eliminated through optimization and improvement.This method serves as a valuable reference for other applications utilizing long-wave infrared detectors in imaging.
作者
李娟
高璐
陈彦冠
付志凯
张磊
LI Juan;GAO Lu;CHEN Yan-guan;FU Zhi-kai;ZHANG Lei(The 11th Research Institute of CETC,Beijing 100015,China;The 6th Military Representative Office of Rocket Army in Beijing Region,Beijing 100074,China)
出处
《激光与红外》
北大核心
2025年第4期575-578,共4页
Laser & Infrared
关键词
长波探测器
碲镉汞
暗环
long-wave infrared detector
HgCdTe
dark ring