摘要 液化天然气(LNG)在储罐中因温度变化易导致分层和翻滚等问题,如不能有效监测罐内温度变化,会造成严重的安全隐患。介绍了LNG储罐温度计的选型、设计方案,在储罐内罐表面和内罐罐底设置1套多点温度计,在内罐外壁和内外罐环隙空间设置1套多点温度计,并设置2套平均温度计,通过测量储罐不同液位的平均温度有效监测罐内LNG状态。对比分析了平均温度计和多点温度计的工作原理和应用特点,总结了2种类型温度计的安装注意事项。实际应用表明,2种类型温度计组合应用,能够提升温度计量准确性,有效提升LNG储罐运行的安全性。 Regarding the issues of layering and rolling of liquefied natural gas(LNG)in storage tanks during storage,serve safety risk will be resulted if the temperature in the tank is not efficiently monitored.The selection and design scheme of LNG tank thermometer are introduced,one set of multi-point thermometer is set on the inner wall and bottom of the inner tank,the other is set on the outer wall and the annulus of the inner and outer tank,and one set of average thermometer is set,the statues of LNG in storage tank will be monitored efficiently by measuring the average temperature of different liquid levels in the tank.The working principle and applying characteristics of average thermometer and multi-point thermometer are compared and discussed,the installation issues for these two kinds of thermometer are introduced.The practical application results shows that the combination of these two kinds of thermometer can increase the metering accuracy,and efficiently improve the safety of the LNG storage tank operation.
作者 沈华志 刘帅 唐孟 吕茂盛 Shen Zhihua;Liu Shuai;Tang Meng;LüMaosheng(Zhejiang Lunte Electromechanical Co.Ltd.,Wenzhou,325600,China;Synfuels China Engineering Co.Ltd.,Beijing,101407,China)
出处 《石油化工自动化》 2025年第2期74-77,共4页 Automation in Petro-chemical Industry
关键词 液化天然气储罐 多点温度计 平均温度计 温度监控 liquefied natural gas storage tank multi point thermometer average thermometer temperature monitoring
  • 相关文献

参考文献6

二级参考文献29

共引文献81

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部