摘要
以Zick法为基础 ,对四支座卧式容器的塌陷失效进行了分析并提出了修复方法。分析结果表明 ,卧式容器的安装方式不合理。
Based on the Zick method, the buckling failure of a four-supporter horizontal vessel was analyzed, and some repair methods were proposed. The results show that the direct causes of the buckling of the vessel were because of the unreasonable installations, incorrect installation heightf othe four supporters, and the level error induced with the nonuniform sinking of the foundation.
出处
《化工机械》
CAS
2002年第6期348-351,共4页
Chemical Engineering & Machinery