摘要 以某分岔隧道为例,对发生火灾时不同通风方案下隧道内的温度场及烟气的蔓延规律进行了模拟研究,分析了匝道风压、主隧道出口段风压、主隧道加宽段风压对火灾烟气输运特性的影响。工况1与工况2分别采用提高匝道风压与提高主隧道出口段风压的通风方案,对比2种工况下温度场变化得知主隧道出口段通风效果优于匝道。工况3采用提高主隧道加宽段风压的通风方案,随着主隧道加宽段风压的增大,主隧道内高于60℃的高温区域不断缩小,主隧道出口段与匝道2 m高度内温度逐渐降低,主隧道加宽段风压的增大对隧道排烟有利,但并不显著。工况4采用增大匝道风压的通风方案,主隧道2 m高度内温度降低,匝道2 m高度内温度升高,增大匝道风压,匝道的排烟效果明显,由于匝道断面小,可考虑作为排烟通道。 Taking a bifurcated tunnel as an example,a simulation study is carried out on the temperature field and smoke spread law in the tunnel under different ventilation schemes during a fire,and the impacts of the wind pressure in the ramp,the wind pressure in the exit section of the main tunnel,and the wind pressure in the widened section of the main tunnel on the smoke transportation characteristics of the fire are analysed.The ventilation scheme of increasing the wind pressure in the ramp and the exit section of the main tunnel is adopted in condition 1 and condition 2,respectively.Comparing the temperature field changes under the two conditions,it is found that the ventilation effect in the exit section of the main tunnel is better than that in the ramp.Condition 3 adopts a ventilation scheme to increase the wind pressure in the widened section of the main tunnel.As the wind pressure in the widened section of the main tunnel increases,the high temperature area above 60℃in the main tunnel continues to shrink,and the temperature within the height of 2 m in the exit section of the main tunnel and the ramp gradually decreases.The increase of the wind pressure in the widened section of the main tunnel is beneficial to tunnel smoke exhaust,but it is not significant.Condition 4 adopts the ventilation scheme of increasing the wind pressure in the ramp.The temperature within the height of 2 m in the main tunnel decreases,and the temperature within the height of 2 m in the ramp increases.If the wind pressure in the ramp is increased,the smoke exhaust effect of the ramp is obvious.Due to the small cross-section of the ramp,it can be considered as a smoke exhaust channel.
作者 曾捷 杜春 赖祺宇 余翔 李树林 Zeng Jie;Du Chun;Lai Qiyu;Yu Xiang;Li Shulin(Shenzhen Expressway Construction and Development Co.,Ltd.,Shenzhen;Chang’an University,Xi’an)
出处 《暖通空调》 2025年第1期70-79,共10页 Heating Ventilating & Air Conditioning
关键词 分岔隧道 火灾 排烟 烟气输运 通风 风压 主隧道 匝道 bifurcated tunnel fire smoke exhaust smoke transportation ventilation wind pressure main tunnel ramp
  • 相关文献

参考文献12

二级参考文献46

  • 1王迪军,罗燕萍,李梅玲.地铁隧道火灾人员疏散与烟气控制[J].消防科学与技术,2004,23(4):345-347. 被引量:35
  • 2王晓雯,蒋树屏.公路长隧道纵向组合通风计算方法及应用[J].中国公路学报,1996,9(3):62-71. 被引量:16
  • 3于丽,王明年,郭春.秦岭特长公路隧道火灾温度场的数值模拟[J].土木工程学报,2007,40(6):64-68. 被引量:14
  • 4LI Y Z,INGASON H. Model Scale Tunnel Fire Tests with Automatic Sprinkler[J]. Fire Safety Journal, 2013,61 (10) : 298-313.
  • 5YI L,NIU J L, XU Z S, et al. Experimental Studies on Smoke Movement in a Model Tunnel with Longitudi- nal Ventilation [J] . Tunnelling and Underground Space Technology, 2013,35:135-141.
  • 6LEE Y P,TSAI K C. Effect of Vehicular Blockage on Critical Ventilation Velocity and Tunnel Fire Behavior in Longitudinally Ventilated Tunnels [J]. Fire Safety Journal,2012,53(10) ..35-42.
  • 7OKA Y, ATKINSON G T. Control of smoke flow in tunnel fires [J]. Fire Safety Journal, 1995, 25(4) : 305 -322.
  • 8WU Y, BAKAR M Z A. Control of smoke flow in tunnel fires using longitudinal ventilation systems-a study of the critical velocity [ J ]. Fire Safety Journal, 2000, 35 (4) : 363 - 390.
  • 9LI Y Z, LEI B, INGASON H. Study of critical velocity and back layering length in longitudinally ventilated tunnel fires [ J ]. Fire Safety Journal, 2010, 45(6/7/8) ; 361 -370.
  • 10LEE Y P, TSAI K C, Effect of vehicular blockage on critical venti-lation velocity and tunnel fire behavior in longitudinally ventilated tunnels[ J] . Fire Safety Journal, 2012 , 53 : 35 -42.

共引文献81

同被引文献8

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部