摘要 苏州河河口水闸为底轴驱动翻板门,在长期运行过程中出现了门叶中缝止水结构损坏漏水情况,漏水呈喷射状,影响水闸安全运行及外滩景观形象。因受外河潮水涨落影响和周边风貌区管理等条件限制,传统施工方案难以维修。为此,本文设计创造了静水作业条件和安装时定位调节等施工方案,并阐明了维修方案实施的详尽步骤,可供类似工程施工参考。 The Suzhou River Estuary Sluice employs a bottom-axis-driven flap gate.Over prolonged operation,the central seam waterstop structure of the gate leaf has been damaged,leading to water leakage.The leakage,characterized by a jetlike spray,compromises the safe operation of the sluice and affects the scenic image of the Bund area.Due to the tidal fluctuations of the outer river and restrictions from the management of the surrounding landscape zone,traditional construction methods are difficult to employ for repairs.Consequently,this paper designs and innovates construction solutions that create static water working conditions and adjust positioning during installation.It also elucidates the detailed steps for implementing the maintenance plan,providing a reference for similar engineering projects.
作者 李志 LI Zhi(Shanghai Levee,Pump and Gate Construction Operation Center,Shanghai 200080,China)
出处 《水利建设与管理》 2024年第11期74-80,共7页 Water Conservancy Construction and Management
关键词 苏州河河口水闸 橡胶止水 维护方案 调节支座 Suzhou River Estuary Sluice rubber waterstop maintenance plan adjustable support
  • 相关文献

参考文献2

二级参考文献7

  • 1季永兴,卢永金,陈文伟,饶建江.苏州河河口水闸工程设计特色[J].上海水务,2006,22(2):3-5. 被引量:4
  • 2陈文伟,季永兴,等.苏州河河口水闸工程技施设计报告[R].杭州:中国水电顾问集团华东勘测设计研究院,2006.
  • 3陈文伟,季永兴,等.苏州河河口水闸工程初步设计报告[R].杭州:中国水电顾问集团华东勘测设计研究院,2003.
  • 4苏州河河口水闸工程初步设计评审报告[R].上海:上海市建设和管理委员会科学技术委员会,2003.
  • 5苏州河河口水闸工程初步设计(工程技术部分)的批复(沪建建规)[2003]799号[R].上海:上海市建设和管理委员会科学技术委员会,2003.
  • 6国家电力公司华东勘测设计研究院,上海市水利工程设计研究院.苏州河河口水闸工程工程可行性研究报告[R].杭州:中国水电顾问集团华东勘测设计研究院,2002.
  • 7关于苏州河河口水闸工程可行性研究报告的批复(沪计城[2003]041号[R].上海:上海市建设和管理委员会科学技术委员会,2003.