摘要
为了研究高炉炉顶气密箱的更换技术,通过详细论述气密箱的安装、维护过程,并对炉顶法兰的平面度重新测量校准;在试车时详细对比了齿轮高低速旋转和倾动升降下的电流变化情况并对气密箱内溜槽实际倾动角度和显示角度进行了分析;结果表明当平面度最大误差在2.5mm, 60°范围内的平面度误差在0~2mm,倾动角度误差不大于0.5°时,对气密箱的安装、运行无影响,气密性强,布料准确。
In order to study the replacement technology of blast furnace top gas-tight box,the installation and maintenance process of the airtight box are discussed in detail,and the flatness of the furnace top flange is re-measured and calibrated.During testing;Detailed comparison of current changes under high and low speed rotation and tilting lifting of gears,And the actual tilting angle and display angle of the chute in the airtight box were analyzed,The results show that when the maximum flatness error is 2.5 mm,the flatness error in the range of 600 is 0~2 mm,and the inclination error is less than 0.5°,there is no influence on the installation and operation of the airtight box.And strong air tightness,cloth accurate.
作者
翟文明
高建明
安庆宏
苗博
Zhai Wenming;Gao Jianming;An Qinghong;Miao Bo(ShanXi TaiGang Stainless Steel Co.,Ltd.,Taiyuan 030000)
出处
《冶金设备》
2024年第4期48-51,共4页
Metallurgical Equipment
关键词
高炉
气密箱
维护
Blast furnace
Airtight box
Maintenance