该项目是集酒店、公寓、办公及商业于一体的超高层建筑综合体。主要从空调冷热源、空调水系统两方面介绍了该工程塔楼区域空调系统设计方案,并在总结梳理前人工作的基础上重点对空调水系统竖向分区进行了研究,指出熟悉设备及管道系统承压能力并对其充分利用是做好超高层空调水系统竖向压力分区的前提。
This project is a super high-rise building complex that integrates hotels,apartments,offices,and commerce.This paper mainly introduces the scheme design of the air conditioning system in the tower area of the project from two aspects:air conditioning cold and heat sources and air conditioning water system.Based on the summary and sorting of previous work,the vertical zoning of the air conditioning water system is studied with emphasis.It points out the premise of being familiar with the pressure capacity of equipment and pipeline systems and fully utilizing them to do a good job in the vertical pressure zoning of the super high-rise air conditioning water system.
作者
张小怀
刘猛
孙洁
周文波
Zhang Xiaohuai;Liu Meng;Sun Jie;Zhou Wenbo(Shanghai Urban Construction Vocational College,Shanghai,200438;Shanghai Baichenghang Construction Engineering Technology Consulting Co.,Shanghai,200041)
出处
《制冷与空调(四川)》
2024年第3期399-405,共7页
Refrigeration and Air Conditioning
关键词
超高层建筑
冷热源
空调水系统
竖向分区
Super high-rise building
Cold and heat sources
Air conditioning water system
Vertical zoning