摘要
目的:采用电感耦合等离子体质谱法(Inductively Coupled Plasma Mass Spectrometry,ICP-MS)测定山药中汞、砷、镉、铅、铜的含量。方法:采用微波消解法处理样品,以铋(209Bi)、锗(72Ge)、铟(115In)为内标,通过ICP-MS测定5种有害元素的含量。结果:汞在0~10.0μg·L^(-1)、砷在0~50μg·L^(-1)、镉在0~20μg·L^(-1)、铅在0~50μg·L^(-1)、铜在0~500μg·L^(-1)浓度范围内线性关系良好(r≥0.9996)。精密度实验得出,5种有害元素的相对标准偏差均≤2.2%;5种有害元素回收率分别为84.7%、87.8%、84.7%、81.9%和87.2%,相对标准偏差≤2.9%。结论:该方法简便快捷、准确度高,可用于同时测定山药中5种有害元素的含量。
Objective:Determination of harmful elements such as mercury,arsenic,cadmium,lead,and copper in yam by inductively coupled plasma mass spectrometry(ICP-MS).Method:Microwave digestion was used to treat samples,with 209Bi,72Ge,115In as internal standards.The content of five harmful elements was determined by ICP-MS.Result:The linear relationship was good within the concentration range of 0~10.0μg·L^(-1) for mercury,0~50μg·L^(-1) for arsenic,0~20μg·L^(-1) for cadmium,0~50μg·L^(-1) for lead,and 0~500μg·L^(-1) for copper.Precision test showed that the relative standard deviation of five harmful elements was less than 2.2%;the recoveries of mercury,arsenic,cadmium,lead and copper were 84.7%,87.8%,84.7%,81.9%and 87.2%,and the relative standard deviation was less than 2.9%.Conclusion:This method is simple,fast,and highly accurate,can be used to simultaneously determine the content of five harmful elements in yam.