摘要
建筑热工设计分区是建筑热工设计的基础,合理的建筑热工设计分区对指导当地建筑热工设计至关重要。本文基于我国现行GB 50176-2016《民用建筑热工设计规范》中规定的分区方法,采用更新的气象数据与新增台站对全国重新进行了热工区划,并与原有的354个城镇的热工区属进行了对比分析,根据分析结果指出了原有热工分区存在的一些问题,并提出了初步的分区指标阈值修正方案。本研究可为建筑热工分区的完善工作提供基础支持。
Climate zoning is the basis of building thermal design.Rational results of climate zoning are crucial for thermal design of local buildings.Based on the zoning method in Code for Thermal Design of Civil Building(GB 50176-2016),the new meteorological data and newly⁃built stations were used to reorganize the thermal zoning in China.A comparative analysis was also conducted with the existing thermal design zoning of 354 cities and towns.The results revealed some significant problems existing in the original thermal zoning,and proposed a preliminary zoning variables correction scheme.The research can provide support for the improvement of climate zoning for building thermal design.
作者
吕凯琳
刘衍
杨柳
董宏
高庆龙
LYU Kailin;LIU Yan;YANG Liu;DONG Hong;GAO Qinglong(State Key Laboratory of Green Building in Western China,Xi’an 710055,China;School of Architecture,Xi’an University of Architecture and Technology,Xi’an 710055,China;China Academy of Building Research,Beijing 100013,China;College of Architecture and Environment,Sichuan University,Chengdu 610000,China)
出处
《建筑科学》
CSCD
北大核心
2022年第10期144-151,共8页
Building Science
基金
国家自然科学基金重点项目(51838011)
国家自然科学基金面上项目(52078407)。
关键词
建筑热工设计分区
分类算法
分区指标
climate zoning for building thermal design
classification method
zoning variables