摘要
介绍ZPW-2000R型轨道电路区段电气绝缘节原理及邻区段越区传输原因,通过对现场越区传输干扰问题的处理,总结越区传输干扰问题的产生原因以及处理方法,为后续处理同样故障提供技术支持。
This paper introduces the principle of electrical separation joint in ZPW-2000R track circuit section and the causes of over-zone transmission.Through dealing with the problem of over-zone transmission interference on site,this paper summarizes the causes and treatment methods of over-zone transmission interference,which provides technical support for the follow-up treatment of the same fault.
作者
张龙
黄春雷
郭虹利
Zhang Long;Huang Chunlei;Guo Hongli
出处
《铁路通信信号工程技术》
2022年第S01期36-39,共4页
Railway Signalling & Communication Engineering
关键词
ZPW-2000R型轨道电路
电气绝缘节
隔离系数
越区传输干扰
故障分析
ZPW-2000R track circuit
electrical separation joint
isolation coefficient
over-zone transmission interference
fault analysis