期刊文献+

Non-Newtonian Effect on Hemodynamic Characteristics of Blood Flow in Stented Cerebral Aneurysm

原文传递
导出
摘要 Stent placement is considered as a promising and minimally invasive technique to prevent rupture of aneurysm and favor coagulation mechanism inside the aneurysm.Many scholars study the effect of the stent on blood flow in cerebral aneurysm by numerical simulations,and usually regard blood as the Newtonian fluid,blood,however,is a kind of non-Newtonian fluid in practice.The main purpose of the present paper is to investigate the effect of non-Newtonian behavior on the hemodynamic characteristics of blood flow in stented cerebral aneurysm with lattice Boltzmann method.The Casson model is used to describe the blood non-Newtonian character,which is one of the most popular models in depicting blood fluid.In particular,hemodynamic characteristics derived with Newtonian and non-Newtonian models are studied,and compared in detail.The results show that the non-Newtonian effect gives a great influence on hemodynamic characteristics of blood flow in stented cerebral aneurysm,especially in small necked ones.
出处 《Communications in Computational Physics》 SCIE 2013年第3期916-928,共13页 计算物理通讯(英文)
基金 financially supported by the National Natural Science Foundation of China(Grant Nos.51006040,and 51006039) the Fundamental Research Funds for the Central Universities,Hust(Grant Nos.2010QN057 and 2010MS131).