本文基于现有10 kV跌落熔断器结构,设计了一种具备自动重合闸、远程主动拉合功能的自动更换熔丝的跌落熔断器,并对10 kV自动更换式跌落熔断器的设计结构进行电场、温度环境理论和仿真分析,最终验证了10 kV自动更换式跌落熔断器的设计可行。
In this paper,based on the existing 10 kV drop fuse structure,design a kind of have the function of automatic reclosing,remote active automatically change the fuse drop fuse,and 10 kV automatic replacement type drop fuse design structure of the electric field and the temperature environment theory and simulation analysis,the final validation for 10 kV automatically change the design of the falling type fuse is feasible.