期刊文献+

转动弹量热计的建立及对氯苯甲酸热值测定 被引量:11

The Construction of a Rotating-Bomb Combustion Calorimeter and the Determination of the Heat of Combustion of p-Chlorobenzoic Acid
在线阅读 下载PDF
导出
摘要 元素有机物要达到完全的燃烧应当在转动弹量热计中进行,这种量热计与静止弹量热计比较有许多优点。首先,转动的结果起到了对弹液的搅拌作用,使弹内各部分溶液的浓度很快达到平衡。其次,促进了燃烧过程中某些副反应的进行,从而短期获得稳定的反应终态,使燃烧热测量的精度显著提高。 A precision rotating-bomb calorimeter was calibrated in this laboratory. The energy equivalent of the calorimeter was calibrated by benzoic acid of purity 99.999 mol percent, which was determined in the laboratory of the Institute of Measurement Science of China. The precision of the results of the calibration experiments was expressed in s.d.m. equal to 0.13%.Using this calorimeter, the heat of combustion -△Eco of p-Chlorobenzoic acid was determined to be 3070,8 ±11 KJ/mol.
作者 杨新法 杨旭武 张正工 孙玲珍 Yang Xinfa;Yang Xuwu;Zhang Zhenggong;Sun Lingzhen(Northwestern University,Xian;Xi’are Medical College Xi’an;Xi’an Institute of Chemical Iudustry,Xi’an)
出处 《高等学校化学学报》 SCIE EI CAS 1986年第4期363-365,共3页 Chemical Journal of Chinese Universities
  • 相关文献

同被引文献52

引证文献11

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部