期刊文献+

三维适形放射治疗前肿瘤CT定位扫描技术的应用价值

Application value of CT localization of tumor before three dimensional conformal radiotherapy
暂未订购
导出
摘要 目的探讨三维适形放射治疗(3DCRT)前肿瘤CT定位扫描技术的应用价值。方法回顾性分析2017年1月至2018年12月福建省漳州市医院收治的35例恶性肿瘤患者的临床资料,所有患者均在3DCRT治疗前行CT定位扫描,观察患者影像学资料与疗效随访结果。结果35例患者中,30例(85.71%)影像学图像显示靶区定位准确,病灶与周围组织分界清晰;5例(14.29%)影像学图像显示病灶与周围组织分界欠佳,行增强CT扫描后影像学图像显示病灶与周围组织分界清晰,满足3DCRT需求;35例在放射治疗后随访1年,其中10例完全缓解,14例部分缓解,7例病情稳定,4例疾病进展,治疗总有效率为68.57%。结论恶性肿瘤患者在3DCRT放射治疗前行CT定位扫描,可清晰显示肿瘤分界,准确定位肿瘤大小及中心坐标,达到适形的效果,有助于提高治疗效果。 Objective To investigate the application value of CT location scanning technology of tumor before 3DCRT.Methods The clinical data of 35 patients with malignant tumors from January 2017 to December 2018 in Zhangzhou Municipal Hospital of Fujian Province were collected retrospectively.All patients were scanned with CT before 3DCRT treatment,and the image data and follow-up results were observed.Results Among the 35 patients,30(85.71%)showed accurate target location and clear boundary between the focus and surrounding tissues;5(14.29%)showed poor boundary between the focus and surrounding tissues.After enhanced CT scanning,the boundary between the image focus and surrounding tissues was clear,meeting the needs of 3DCRT.Follow-up for 1 year showed that the total effective rate was 68.57%in 10 cases of complete remission,14 cases of partial remission,7 cases of stable condition and 4 cases of disease progression.Conclusion CT localization scan before 3DCRT radiotherapy can clearly show tumor boundary,accurately locate tumor size and central coordinate,achieve conformal effect and improve treatment effect.
作者 谢剑君 胡苏靖 王燕玲 XIE Jianjun;HU Sujing;WANG Yanling(Zhangzhou Municipal Hospital of Fujian Province,Fujian 363000,China)
出处 《医疗装备》 2020年第22期3-4,共2页 Medical Equipment
关键词 肿瘤 三维适形放射治疗 影像学检查 定位扫描 Tumor Three-dimensional conformal radiotherapy Imaging examination Positioning scan
  • 相关文献

参考文献5

二级参考文献60

  • 1Welsh J, Settle $H, Amini A, et al. I=ailure patterns in patients with esophageal cancer treated with definitive chemoradiation[J]. Can- cer, 2012, 118(10):2632-2640.
  • 2Kole TP, Aghayere O, Kwah J, et al. Comparison of heart and coro- nary artery doses associated with intensity-modulated radiothera- py versus three-dimensional conformal radiotherapy for distal esophageal cancer[J]. Int J Radiat Oncology Biol phys, 2012, 83(5): 1580-1586.
  • 3Aggarwal A, Harrison M, Glynne-Jones R, et al. Combination external beam radiotherapy and intraluminal brachytherapy for non-radical treatment of oesophageal carcinoma in patients not suitable for surgery or chemoradiation[J]. Clinical Oncology, 2015, 27(1):56-64.
  • 4Grills IS, Yah D, Martinez AA, et al. Potential for reduced toxicity and dose escalation in the treatment of inoperable non-small-cell lung cancer:a comparison of intensity-modulated radiation therapy (IMRT), 31) conformal radiation, and elective nodal irradiation [ J ].Int J Radiat Oncal Biol Phys,2003,57 ( 3 ) : 875-890.DOI : 10. 1016/S0360-3016(03) 00743-0.
  • 5Qi LP, Zhang XP, Tang L, et al. Using diffusion-weighted MR imaging for tumor detection in the collapsed lung: a preliminary study [J]. Eur Radiol, 2009, 19 ( 2 ) : 333-341. DOI: 10. 1007/ s00330-008-1134-3.
  • 6ICRU. ICRU Report 62: Prescribing, recording and reporting photon beam therapy ( Supplement to ICRU report 50 ) [ R]. Bethesda, MD: International Commission on Radiation Units and Measurements, 1999 : 125-210.
  • 7Ettinger DS, Wood DE, Akerley W, et al. NCCN clinical practice guidelines in oncology non-small cell lung cancer (version 3. 2015) ,principles of radiation therapy ( 7 of 9) [ EB/OL] .Fort Washington: blCCN, 2015 [ 2015-06-11 ]. http ://www. ejcpt, org/ files/2015/03 -06/2015 -NCCN/2015 % 20NCCN-NSCLC-V 3. pdf.
  • 8ICRU. ICRU Report 83: prescribing, recording, and reporting photon-beam intensity modulated radiation therapy (IMRT) [ J ]. J ICRU, 2010, I0 ( 1 ) : NP.DOI : 10.1093/jicru/ndq002.
  • 9Knf6s T, Kristensen I, Nilsson P. Volumetric and dosimetric evaluation of radiation treatment plans:radiation conformity index [ J ] .Int J Radiat Oncol Biol Phys, 1998,42 (5) :1169-1176.DOI: 10.1016/S0360-3016 ( 98 ) 00239-9.
  • 10Molina PL, Hiken JN, Glazer HS.Imaging evaluation of obstructive atelectasis [ J] .J Thorac Imaging, 1996,11 (3) : 176-186.