期刊文献+

CAD/CAM陶瓷树脂复合体材料在超薄嵌体应用中的疲劳性能研究 被引量:7

A study on the fatigue properties of CAD/CAM ceramic/resin composites used in ultrathin overlays
暂未订购
导出
摘要 目的:研究CAD/CAM陶瓷树脂复合体材料与玻璃陶瓷材料在超薄嵌体应用中的疲劳性能差异。方法:将40颗离体前磨牙预备成深1mm的超薄嵌体洞型,使用CAD/CAM系统将Vita Enamic(VE),Lava Ultimate(LU),IPSe.max CAD(IC)和IPS Empress CAD(IE)加工成相应厚度嵌体并粘接。进行185000次循环疲劳试验,记录加载力度,循环次数和破坏模式,使用Kaplan-Meier生存分析比较4组试件的疲劳性能。结果:185000次循环疲劳后LU、VE、IC、IE的存活率分别为80%、50%,30%,0%,平均断裂载荷为1360、1280、1200和820N(P<0.05)。结论:VE、LU的疲劳性能与IC相当,均优于IE。 Objective: To study the fatigue property of CAD/CAM ceramic resin composites used in ultrathin overlays. Methods: An ultra-thin overlay cavity with a depth of 1 mm was prepared in each of 40 premolars, the overlays were fabricated with Vita Enamic(VE), Lava Ultimate(LU), IPS e.max CAD(IC) and IPS Empress CAD(IE) respectively(n=10) by CAD/CAM system and bonded into the overlay cavities on the teeth.Then the specimens were subjected to cyclic fatigue test. When fracture occurred or the cycle ended, the loading force, cycle times and failure mode were observed, then Kaplan-meier survival analysis was used to compare the fatigue performance of the 4 groups. Results: The survival rates of LU, VE, IC and IE were 80%, 50%, 30% and 0%(P<0.05), the average fracture strength was 1 360, 1 280, 1 200 and 820 N(P<0.05), respectively. Conclusion: VE, LU and IC have similarly stronger fatigue resistivity than IE.
作者 吴传兴 林敏 陈铭晟 甘宁 王璐 WU Chuanxing;LIN Min;CHEN Mingsheng;GAN Ning;WANG Lu(Stomatological Hospital of Chongqing Medical University,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences,China,401147;Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education)
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2020年第4期581-585,共5页 Journal of Practical Stomatology
基金 重庆市渝北区科委课题(编号:2017〔农社〕45) 2016年重庆高校创新团队建设计划资助(编号:CXTDG201602006)。
关键词 超薄嵌体 CAD/CAM材料 疲劳试验 Ultrathin overlay CAD/CAM material Fatigue test
  • 相关文献

参考文献2

二级参考文献36

  • 1Ernst CP, Canbek K, Euler T, et al. In vivo validation of the historical in vitro thermocycling temperature range for dental materials testing[J]. Clin Oral Investig, 2004, 8 (3) : 130-138.
  • 2Gale MS, Darvell BW. Thermal cycling procedures for laboratory testing of dental restorarions[J]. J Dent, 1999, 27 (2) : 89-99.
  • 3Heintze SD, Cavalleri A, Forjanic M, et al. Wear of ce- ramic and antagonist-a systematic evaluation of influen- cing factors in vitro[J]. Dent Mater, 2008, 24 (4):433- 449.
  • 4Beuer F, Steff B, Naumann M, et al. Load-bearing ca- pacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD) /computer- aided manufacturing (CAM) fabricated framework mate- rials[J]. Eur J Oral Sci, 2008, 116(4):381-386.
  • 5Atria A, Abdelaziz KM, Freitag S, et al. Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns[J]. J Prosthet Dent, 2006, 95 (2):117-123.
  • 6Baran G, Boberick K, McCool J. Fatigue of restorative materials[J]. Crit Rev Oral Biol Med, 2001, 12(4):350- 360.
  • 7Jung YG, Peterson IM, Kim DK, et al. Lifetime-limiting strength degradation from contact fatigue in dental cera- mics[J]. J Dent Res, 2000, 79(2):722-731.
  • 8Vuh yon Steyern P, Ebbesson S, Holmgren J, et ak Fra- cture strength of two oxide ceramic crown systems after cyclic pre-loading and thermocycling[J]. J Oral Rehabil, 2006, 33 (9) : 682-689.
  • 9Heintze SD, Cavalleri A, Zellweger G, et al. Fracture fre- quency of all-ceramic crowns during dynamic loading in a chewing simalator using different loading and luting protocols[J]. Dent Mater, 2008, 24(10): 1352-1361.
  • 10Kim JW, Bhowmick S, Chai H, et al. Role of substrate material in failure of crown-like layer structures[J]. J Biomed Mater Res B Appl Biomater, 2007, 81 (2):305- 311.

共引文献8

同被引文献53

引证文献7

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部