摘要
针对目前分体空调双排冷凝器紧贴布置方式影响换热效果的现状,提出了优化双排冷凝器布置间距的措施。分别测试了双排冷凝器0,5,10,15,20,25 mm间距下分体空调的运行状况,结果表明,15~20 mm间距范围内空调制冷效果得到明显改善,节能效果显著。
In view of the current situation that the close arrangement of double row condensers of split air conditioner affects the heat exchanging effect,puts forward the measures to optimize the arrangement distance of double row condensers.Tests the operating conditions of the split air conditioner with 0,5,10,15,20,25 mm distance of double row condensers respectively,and the results show that the cooling effect of air conditioner in the distance range from 15 to 20 mm is obviously improved,and the energy saving effect is remarkable.
作者
贺广兴
朱福
He Guangxing;Zhu Fu(Tongren Polytechnic College,Tongren,Guizhou Province,China;不详)
出处
《暖通空调》
2020年第7期118-119,67,共3页
Heating Ventilating & Air Conditioning
基金
铜仁科技计划资助项目(编号:2017TRS66507)。
关键词
分体空调
双排冷凝器
布置间距
制冷效果
节能
split air conditioner
double row condenser
arrangement distance
cooling effect
energy efficiency