期刊文献+

扫频光相干断层扫描生物测量仪OA-2000的临床应用研究进展

Research progress in clinical application of a swept-source optical coherence tomography biometer OA-2000
在线阅读 下载PDF
导出
摘要 随着白内障超声乳化联合人工晶状体植入技术的提高,眼科医生及患者越来越重视术后效果,用于白内障术前测量的检查设备也在不断发展,各类眼部生物参数测量仪器应运而生,已经从超声原理发展到扫频光源光学相干层析成像原理。近来新上市的眼部生物测量仪器OA-2000全自动三维扫频生物测量仪是一种新型扫频光相干断层扫描成像(SS-OCT)设备,具有操作简便安全、分辨率高、重复性好、测量速度快及组织穿透好等特点,一次测量可获得多个眼部生物参数,具有广泛的应用前景。本文就OA-2000测量原理及临床应用进展进行综述。 ·With the advances in cataract phacoemulsification and intraocular lens implantation,more and more attention has been paid to the postoperative effects by both clinicians and patients.Meanwhile,the instruments for the preoperative measurements are also evolving.Various types of ocular biometers have emerged,which have evolved the principles from ultrasound to swept-source optical coherence tomography(SS-OCT).The OA-2000,a new type of SS-OCT based ocular biometer with fully automatic three-dimensional scanning,has the advantages of simple and safe operation,high resolution,excellent repeatability,fast measurement and good tissue penetration.It can obtain multiple ocular biological parameters in one measurement,which enables a wide application prospect.Here,we review the measurement principle and clinical application of OA-2000.
作者 刘波 廖萱 兰长骏 Bo Liu;Xuan Liao;Chang-Jun Lan(Department of Ophthalmology,Affiliated Hospital of North Sichuan Medical College,Nanchong 637000,Sichuan Province,China;Department of Ophthalmology&Optometry,North Sichuan Medical College,Nanchong 637000,Sichuan Province,China)
出处 《国际眼科杂志》 CAS 北大核心 2020年第8期1375-1378,共4页 International Eye Science
基金 四川省卫计委重点课题项目(No.18ZD022)。
关键词 OA-2000 眼部生物测量 临床应用 扫频光相干扫描成像 重复性 一致性 OA-2000 ocular biometrics clinical application optical low coherent reflectometry repeatability consistency
  • 相关文献

参考文献9

二级参考文献32

  • 1Ziad Hassan,Laszlo Modis,Eszter Szalai,Andras Berta,Gabor Nemeth.Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking[J].International Journal of Ophthalmology(English edition),2014,7(2):313-316. 被引量:1
  • 2殷鸿波,邓应平,邱乐梅.Mydrin-P散瞳前后中央角膜厚度的变化(英文)[J].国际眼科杂志,2006,6(1):25-26. 被引量:9
  • 3孙兰萍,刘桂芬,任延军,郝俊华,李冀,张亚娟.近视眼患者散瞳前后角膜厚度的比较[J].眼科研究,2006,24(5):517-517. 被引量:3
  • 4黄振平.屈光手术的最新技术及其临床应用[J].医学研究生学报,2007,20(4):337-338. 被引量:24
  • 5Jin H. Holzer MP. Rabsilber T. et at. Intraocular lens power calculation after laser refractive surgery: corrective algorithm for corneal power estimation [J]. J Cataract Refract Surg , 2010. 36 (1) :87-96.
  • 6Olsen T. Calculation of intraocular lens power: a review[J]. Acta Ophthalmol Scand,2007 ,85(5) :472-485.
  • 7Jin GJ, Crandall AS, Jones J], Intraocular lens exchange due to incorrect lens power [J]. Ophthalmology, 2007, 114 (3) : 417-424.
  • 8Buckhurst P J, W olffsohn J S, Shah S, et al. A new optical low coherence reflectometry device for ocular biometry in cataract patients[J]. Br J Ophthalmol, 2009,93 (7) : 949-953.
  • 9Rohrer K, Frueh B E, Walti R, et al. Comparison and evaluation of ocular biometry using a new noncontact optical low-coherence reflectometer [J]. Ophthalmology, 2009, 116 (11) : 2087-2092.
  • 10Santodomingo- Rubido J, Mallen EA, Gilmartin B, et al. A new non-contact optical device for ocular biometry [J]. Br J Ophthalmol,2002,86(4) :458-462.

共引文献72

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部