综合管廊火灾自动报警系统设计要点 被引量:3

Key Points of Design of Automatic Fire Alarm System for Utility Tunnel
原文传递
导出
摘要 综合管廊的环境、人员情况有其自身的独特性,本文针对管廊的特性,依据火灾自动报警系统相关规范,结合项目实例,从系统架构、火灾探测器的选择及安装方式等方面对管廊火灾自动报警系统进行设计要点总结及分析. The environment and personnel conditions of the utility tunnel have their own uniqueness.According to the characteristics of the utility tunnel,this paper summarizes and analyzes the design key points of the utility tunnel fire automatic alarm system from the aspects of system architecture,fire detector selection and installation mode according to the relevant specifications of the fire automatic alarm system and the project examples the author participated in.
作者 翁炜姗 戴文涛 蔡晓坚 Weng Weishan;Dai Wentao;Cai Xiaojian(Shenzhen Municipal Design&Research Institute Co.,Ltd.,Shenzhen 518029,China)
出处 《智能建筑电气技术》 2020年第3期45-47,共3页 Electrical Technology of Intelligent Buildings
关键词 火灾自动报警系统 综合管廊:火灾探测器 automatic fire alarm system utility tunnel fire detector