64排螺旋CT双低剂量技术应用于肺动脉CTA的价值 被引量:12

Value of 64-slice spiral CT double low dose technique in pulmonary artery CTA
暂未订购
导出
摘要 目的探讨使用低电压(85 KVp)、低对比剂剂量的条件下,肺动脉CTA的临床应用价值。方法连续收集64例临床怀疑肺动脉栓塞等肺部疾病而做肺动脉CTA病人,研究组使用碘克沙醇(270 mg/mL),85 KVp,共32例,对照组使用碘克沙醇(320 mg/mL),120 KVp,共32例;记录每组CT扫描自动生成的剂量参数,包括剂量长度乘积(DLP)和CT剂量指数(CTDIvol),比较两组图像参数情况,包括辐射剂量、肺动脉内CT值、图像对比噪声比(CNR)及信噪比(SNR)。结果使用双低剂量扫描图像质量主观评分及客观评分中的肺动脉内CT值评分两组差异无统计学意义(P>0. 05),图像质量满足临床诊断要求。在固定其它扫描参数前提下,管电压从120 KVp降至85KVp时,其CTDIvol、DLP分别下降了66. 33%、65. 03%,差异有统计学意义(P <0. 05)。结论64排螺旋CT肺动脉CTA应用双低剂量扫描是可行的,图像质量好能满足临床诊断的需要,同时能显著降低放射剂量。 Objective To explore the clinical value of pulmonary artery CTA under low voltage( 85 KVp) and low contrast dose. Methods Sixty-four patients with pulmonary CTA suspected of pulmonary embolism and other pulmonary diseases were divided into two groups. In the study group,32 patients were treated with ioxanol( 270 mg I/mL),85 KVp,and in the control group,32 patients were treated with ioxanol( 320 mg I/mL),120 KVp. Dose parameters automatically generated by CT scanning in each group were recorded,including dose length product( DLP) and CT dose index( CTDI).And image parameters,including radiation dose,CT value,image contrast noise ratio( CNR) and signal-to-noise ratio( SNR),were compared between the two groups. Results There was no significant difference in subjective score and objective score of image quality and CT value between the two groups( P > 0. 05),and the image quality met the requirements of clinical diagnosis. On the premise of fixing other scanning parameters,CTDIvol and DLP decreased by 66. 33% and 65. 03%respectively when the tube voltage decreased from 120 KVp to 85 KVp( P < 0. 05). Conclusion It is feasible to use double low-dose CT in 64-slice spiral CT pulmonary artery CTA. Good image quality can meet the needs of clinical diagnosis and significantly reduce the radiation dose.
作者 周婷 王刚 ZHOU Ting;WANG Gang(Hubei Hospital of Integrated Traditional Chinese and Western Medicine,Wuhan 430015,China)
出处 《现代医院》 2020年第4期622-624,共3页 Modern Hospitals
关键词 肺动脉 血管成像 双低剂量 CT Pulmonary Artery Angiography Double Low Dose CT
  • 相关文献

参考文献9

二级参考文献85

  • 1Lee HY, Song IS, Yoo SM et al. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography. [J]. Acta Radiologica, 2011,52(4): 378- 384.
  • 2Apfattrer, P. , Henzler, T. , Mey er,M. et al. Correlation of CT angiographic pulmonary artery obstruction scores with right ventricular dysfunction and clinical outcome in patients with acute pulmonary embolism[J]. European Journal of Radiology, 2012, 81(10):2867- 2871.
  • 3ANDREUCCI M,FAGA T,PISANI A,et al.Prevention of contrast-induced nephropathy through a knowledge of its pathogenesis and risk factors[J].Scientific World Journal,2014:823169.
  • 4PALEVSKY P M,LIU K D,BROPHY P D,et al.KDOQI US commentary on the 2012 KDIGO clinical practice guideline for acute kidney injury[J].Am J Kidney Dis,2013,61(5):649-672.
  • 5STACUL F,VAN DER MOLEN A J,REIMER P,et al.Contrast induced nephropathy:updated ESUR Contrast Media Safety Committee guidelines[J].Eur Radio1,2011,21(12):2527-2541.
  • 6Ozsvath K J,Darling R C III.Renal protection:preconditioning for the prevention of contrast-induced nephropathy[J].Seminars In Vascular Surgery,2013,26(4):144-149.
  • 7王于臻,相法伟,刘桂芳,王丽君,柳橙.螺旋CT肺动脉成像低剂量高浓度碘普罗胺对比剂的应用研究[J].中国现代药物应用,2008,2(24):38-39. 被引量:6
  • 8毕涛,徐磊,张兆琪,杨琳,赵蕾,吕滨,韩丹,柳澄,段青.双源CT前瞻性心电门控序列扫描冠状动脉成像准确性的多中心研究[J].中华放射学杂志,2009,43(7):708-713. 被引量:19
  • 9葛全序,毕可森,丛培霞,王培玺,赵锦桥.80kV64排多层螺旋CT低辐射肺动脉成像[J].中华放射医学与防护杂志,2009,29(5):535-539. 被引量:44
  • 10姜英健,于铁链,戴亚楠,刘长宏,苏大同.低剂量CT肺动脉造影的临床研究[J].天津医科大学学报,2010,16(1):166-170. 被引量:5

共引文献99

同被引文献143

引证文献12

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部