摘要
介绍了韶山换流站直流电压动态控制策略,该控制策略旨在减少换流变分接头动作次数。探讨了该控制策略与原控制策略的区别,对直流电压动态控制策略中存在的问题进行了分析,并提出合理建议。
This paper introduces the DC voltage dynamic control strategy of Shaoshan converter station,which aims to reduce the action of times of converter transformer tap-changer.In addition,this paper discusses the difference between the control strategy and the original control strategy,analyzes the problems existing in the DC voltage dynamic control strategy,and puts forward reasonable suggestions.
作者
彭涛
唐恒蔚
李晓武
刘昊然
王应坤
PENG Tao;TANG Hengwei;LI Xiaowu;LIU Haoran;WANG Yingkun(State Grid Hunan Electric Power Company Limited Maintenance Company,Changsha 410004,China)
出处
《湖南电力》
2020年第2期15-20,共6页
Hunan Electric Power
关键词
换流变
分接开关
频繁调节
直流电压动态控制
converter transformer
tap-changer
frequent adjustment
DC voltage dynamic control