摘要
文章利用数值模拟结果分析了上游遮挡物对建筑物屋面光伏阵列风荷载特性的影响。分析结果表明:遮挡物对光伏阵列上的风荷载影响较大;随着遮挡物高度的增加,各光伏板受到的风荷载由升力逐渐转变为压力;当遮挡物与建筑物高度相同时,光伏板受到的风荷载最大,光伏板的最大体型系数约为0.37;遮挡物与建筑物间距的改变对各光伏板的体型系数影响较小。
The paper uses numerical simulation method to analyze the influence of upstream obstructions on the wind load characteristics of building roof mounted PV arrays. The analysis results show that the obstruction has a great influence on the wind load on the PV array;As the height of the obstruction increases, the wind load received by each photovoltaic panel changes gradually from lift to pressure. When the obstruction is the same height as the building, the wind load of the photovoltaic panel is the largest, and the maximum body shape coefficient is about0.37;The change of the distance between the obstruction and the building has little effect on the body shape coefficient of each photovoltaic panel.
作者
江继波
章正暘
陆元明
陈伟
张涛
张建伟
高月锁
缪飞
张大千
吴康宁
王云鹏
Jiang Jibo;Zhang Zhengyang;Lu Yuanming;Chen Wei;Zhang Tao;Zhang Jianwei;Gao Yuesuo;Miu Fei;Zhang Daqian;Wu Kangning;Wang Yunpeng(Shanghai Electric Power New Energy Development Corporation,Shanghai 200010,China;Nanjing Haide Power Technology Corporation,Nanjing 210000,China;Shenyang Aerospace University Aerospace Academy,Shenyang 110136,China)
出处
《可再生能源》
CAS
北大核心
2019年第12期1777-1785,共9页
Renewable Energy Resources
基金
国家自然科学基金(51406124)
关键词
风洞试验
数值模拟
风荷载
建筑遮挡
抗风设计
wind tunnel test
numerical simulation
wind load
building occlusion
wind resistance design