导出
摘要 与传统成像技术相比,荧光成像因具有更高的安全性、更好的空间分辨率和实时性等优点而被广泛应用于临床肿瘤检测和术中导航。目前应用较多的荧光探针主要包括持续发光型和环境响应型,其中环境响应型探针的灵敏度与特异性更好,且可产生较高的信噪比,因而作为应用首选。环境响应型探针主要分为3种,酶激活的探针、pH敏感型探针和乏氧响应型探针。该文总结了环境响应型荧光探针最新的研究进展,并探讨其在肿瘤检测和肿瘤术中导航应用中的潜在价值。 Unlike conventional imaging technologies,fluorescent imaging benefits from its safety,high-spatial resolution and real-time capability,which make it a highly adoptable imaging method for tumor detection and image-guided surgery in clinics.There are two types of fluorescent probes,including always-on type and environment-responsive type,wherein environment-responsive probes are preferred due to higher target-to-background ratios,which can improve sensitivity and specificity.The environment-responsive probes include enzyme-reactive probes,pH-sensitive probes and hypoxia responsive probes.This review summarizes recent progress in environment-responsive probes,and discusses their potentials in tumor detection and image-guided surgery.
作者 朱靖 楚成超 刘刚 Zhu Jing;Chu Chengchao;Liu Gang(Center for Molecular Imaging and Translational Medicine,School of Public Health,Xiamen University,Xiamen 361102,China)
出处 《中华核医学与分子影像杂志》 CAS 北大核心 2019年第11期694-697,共4页 Chinese Journal of Nuclear Medicine and Molecular Imaging
基金 国家重点研发计划 (2017YFA0205201)。
关键词 分子探针 荧光 肿瘤微环境 酶类 氢离子浓度 细胞低氧 发展趋势 Molecular probes Fluorescence Tumor microenvironment Enzymes Hydrogen-ion concentration Cell hypoxia Trends
  • 相关文献

参考文献3

二级参考文献70

  • 1Bani MR, Lux MP, Heusinger K, et al. Factors correlating with re- excision after breast-conserving therapy [ J ]. Eur J Surg Oncol, 2009, 35: 32-37.
  • 2Besana-Ciani I, Greenall MJ. The importance of margins status after breast conservative surgery and radiotherapy in node positive pa- tients: a follow-up of 10-15 years[J]. Int Semin Surg Oncol, 2008, 5: 13.
  • 3Balch GC, Mithani SK, Simpson JF, et al. Aeeuracy of intraopera- tire gross examination of surgical margin status in women undergoing partial mastectomy for breast malignaney[ J]. Am Surg, 2005, 71 : 22-27.
  • 4Chagpar A, Yen T, Sahin A, et al. Intraoperative margin assess- ment reduees reexcision rates in patientswith duetal carcinoma in situ treated with breast-conserving surgery [ J ]. Am J Surg, 2003, 186: 371-377.
  • 5Burke S, Shorten GD. When pain after surgery doesn't go away[J] .. Biochem Soc Trans, 2009, 37: 318-322.
  • 6Tagaya N, Yamazaki R, Nakagawa A, et al. Intraoperative identifi- cation of sentinel lymph nodes by near-infrared fluorescence imaging in patients with breast cancer[J]. Am J Surg, 2008, 195: 850- 853.
  • 7Nakayama A, del Monte F, Hajjar RJ, et al. Functional near-infrared fluorescence imaging for cardiac surgery and targeted gene therapy[J].Mol Imaging, 2002, 1: 365-377.
  • 8Soltesz EG, Kim S, Laurence RG, et al. Intraoperative sentinel lymph node mapping of the lung using near-infrared fluorescent quantum dots[J]. Ann Thorac Surg, 2005, 79: 269-277.
  • 9Troyan SL, Kianzad V, Gibbs-Strauss SL, et al. The FLARE intra- operative near-lnfrared fluorescence imaging system: a first-in-hu- man clinical trial in breast cancer sentinel lymph node mapping[ J]. Ann Surg Oncol, 2009, 16: 2943-2952.
  • 10Withrow KP, Newman JR, Skipper JB, et al. Assessment of bev- acizumab conjugated to Cy5.5 for detection of head and neck cancer xenografts[ J]. Technol Cancer Res Treat, 2008, 7 : 61-66.

共引文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部