摘要 对架空线路用复合绝缘子工频电弧特性的研究表明复合绝缘子相对悬式瓷、玻璃绝缘子而言易遭受工频电弧损坏。其表现为伞裙和护套粉化、电蚀和漏电起痕及碳化严重 ;芯棒暴露和机械强度下降。 The performance of power frequency arc of composite insulators on overhead lines is investigated in this paper. Compared with ceramic or glass insulators, the composite insulator is more easily broken by power frequency arc. Influenced by power frequency arc, the insulators show external housing and sheds chalking, serious erosion and tracking. The core is exposed and mechanical strength is decreased. To protect composite insulator and keep a.c. arc far away from insulator surface, the arc horn should be equipped at cap and pin of composite insulators.
出处 《高电压技术》 EI CAS CSCD 北大核心 2002年第11期9-10,共2页 High Voltage Engineering
关键词 架空线路 复合绝缘子 工频电弧 输电线路 overhead lines composite insulators power frequency arc