期刊文献+

油井采出液处理效果分析及改进措施研究

Disposal of Produced Water:Effect Analysis & Measures for Improvement
在线阅读 下载PDF
导出
摘要 通过对油站和污水站的化学成分分析 ,找出了电脱水器跳闸的原因 :由于污水中的一些成分导致腐蚀 ,腐蚀产生的硫化铁和铁颗粒 ,随着油水混合液在管线中运移 ,在电脱水器上越积越厚 ,致使电脱水器上导电率增高 ,电脱水器跳闸。提出了改善注入水水质 ,减缓腐蚀的有利措施。 By analyzing the chemical elements of the waste water in oil station and sewage disposal plant,the causes for the trip of electric dehydrator are found out.Some elements in the waste water lead to t he corrosion that cause the formation of iron sulfide and iron particles.These s ubstances together with the mixture of oil and water are carried along in the pi peline and are attached to the dehydrator so that the electric conductivity of t he dehydrator is increased and the trip happens.It is suggested that the quality of the input water should be purified to slow down the process of corrosion.
出处 《石油工业技术监督》 2002年第11期47-49,共3页 Technology Supervision in Petroleum Industry
关键词 油井 采出液处理 效果 改进措施 研究 水质 污水处理 Electric dehydrator,Waste wate r,Analysis,Water quality,Oil well
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部