期刊文献+

超声背向散射积分对正常人肾实质的检测 被引量:1

MEASUREMENT OF THE ULTRASOUND INTRASOUN INTEGRATED BACKSCATTER VALUE OF RENAL PARENCHYMA IN NORMAL PERSON
暂未订购
导出
摘要 目的 :测定正常人肾实质超声背向散射积分 (IBS)值 ,为进一步探讨肾实质弥漫性病变打下基础。方法 :将受检者按不同年龄段分组 ,分别测量肾实质及肾窦区的IBS值 ,以二者之比为肾实质标化IBS值。结果 :不同年龄组之间其IBS %值均有差异 (P <0 .0 1)。结论 :正常成人肾实质IBS %值随年龄增长而增加。 Objective:To settle foundation in further studying of diffusive renal parenchyma disease by studying the ultrasound integrateb backscatter (IBS) value of renal panmchyma of normal person.Methods:The people were classified according to their age. The IBS values of renal parenhyma and sinus were measured. The ratio was defined as the revised IBS of renal parenchyma.Results:The IBS% value of renal parenchyma of each group was statistically significantly different in both kidneys. Conclusion:The IBS value of renal parenchyma in adult normal persons increases as their age increases.
出处 《中国现代医学杂志》 CAS CSCD 2002年第20期52-53,共2页 China Journal of Modern Medicine
关键词 超声背向散射积分 正常人 肾实质 检测 Ultrasound Integrated Backscatter Integral Renal Parenchyma
  • 相关文献

参考文献3

  • 1Julio EP, James G, Miller SA, et al. Quantitative ultrasonic imaging: tissue characterization and instantaneous quantification of cardiac function. Am J Cardiol, 1992; 69:104H~ 11 0H
  • 2Insana MF, Wood JG, HaH TJ. Identifying acoustic scattering sources in normal renal parenchyma in vivo by varying arterial and urethral pressures. Ultrasound Med Biol, 1992; 18(6 ~7): 587~599
  • 3Balen FG, Allen CM, Less WP,et al. Review ultrasound contrast agents Clinical Radiology, 1994;49:77~82

同被引文献29

  • 1谭静,唐红.综合超声技术评价尿毒症透析患者心脏病变[J].华西医学,2006,21(1):23-24. 被引量:4
  • 2辛明志,陈艳华,刘凤霞,胡亚萍.慢性肾小球肾炎致慢性肾衰时肝脏超声图表现[J].齐齐哈尔医学院学报,1996,17(4):289-289. 被引量:1
  • 3Feinberg MS, Gussak HM, Davila- Roman VG,et al. Dissociation between wall thickening of normal myocardium and cyclic variation of backscatter during inotropic stimulation. Am J Cardiol, 1996,77 : 515 - 520.
  • 4Nozaki S, DeMaria AN, Helmer GA, et al. Detection of regional left ventriculardysfunction in early pacing - induced heart failure using ultrasonic integrated backscatter. Circulation, 1995,92:2676 - 2682.
  • 5Ito T, Suwa M, Kobashi A, Nakamura T, et al. Influence of propranolol infusion on cyclic variation of myocardial integrated backscatter in hypertrophic obstructive cardiomyopathy. Am J Soc Echocardiogr,2002, 15 ( 10 Pt 2) :1251 - 1255.
  • 6Pacileo G, Calabro P, Limongelli G,et al. Feasibility and usefulness of right ventrieular ultrasonic tissue characterization with integrated backscatter in patients with unsuccessfully operatively" repaired" tetralogy of Fallot. Am J Cardiol,2002,90:669 -671.
  • 7Yuda S. Short L, Leano R, Marwick TH. Myocardial abnormalities in hypertensivepatients with normal and abnormal left ventricular filling:a study of ultrasound tissue characterization and strain. Clin Sci Lond, 2002,103:283 -293.
  • 8Gara BS, Insana MF, Sesterhenn IA, et al. Quantitative ultrasonic detection of parenchymal structural change in diffuse renal disease. Invest Radiol, 1994, 29(2) :134 -140.
  • 9Hall TJ, Insana MF, Harrison LA, et al. Ultrasonic measurement of glomerular diameters in normal adult humans. Ultrasound Med Biol, 1996, 22(8) :987 -997.
  • 10Ansari A, Kaupke CJ, Vaziri ND, et al. Cardiac pathology in patients with end - stage renal disease maintained on hemodialysis. The International Journal of Artificial Organs, 1993,16 ( 1 ) :31 -36.