摘要
基于母线电量平衡分析法基本原理,结合电能计量管理工作经验,对某电厂母线电量不平衡率异常原因进行了分析并给出解决措施。所给出的改造方案能够实现对电厂电量不平衡率的有效控制,实现计量表计准确、公正、可靠运行。
Based on the basic principle of busbar power balance analysis method and the experience of electric energy measurement management,this paper analyzes the cause of abnormal measurement of busbar power imbalance in a power plant and proposes solutions.The proposed scheme can effectively control the unbalanced rate of electric quantity of power plant and realize the accurate,fair and reliable operation of metering meters.
作者
田雨辰
郭安宁
周博曦
TIAN Yuchen;GUO Anning;ZHOU Boxi(State Grid Jinan Zhangqiu Power Supply Company,Jinan 250200,China;State Grid Shandong Electric Power T&T Engineering Co.,Ltd.,Jinan 250011,China;Shandong Electric Power Technical College,Jinan 250002,China)
出处
《山东电力技术》
2019年第9期34-37,共4页
Shandong Electric Power
基金
山东省高等学校科学技术计划项目(J18KB146)
关键词
电能计量
母线电量不平衡率
准确性
electric energy metering
busbar power unbalance rate
accuracy