期刊文献+

15 MW汽轮机组大修后转速飞升的原因分析与处理

Reason Analysis and Treatment of Rapid Speed Rise of 15 MW Steam Turbine Unit after
在线阅读 下载PDF
导出
摘要 根据邯钢西区干熄焦发电2#汽轮机大修后一次开机转速飞升异常现象,对影响汽轮机转速急升的问题进行阐述。在故障排查过程中,修正了调速汽门的线性,恢复了发电机并网开关正常状态,消除了汽轮机转速飞升的异常现象,实现了机组正常并网发电。 Based on the abnormal rapid rise at startup of the CDQ No. 2 steam turbine unit at Handan Steel’s west area after overhaul, the paper discusses about the causes of the excessive speeding up problem. In troubleshooting of the accident, the linearity of the speed regulating throttle was revised, which restored the grid-connection switch of the generator to normal condition, eliminated the excessive speeding up phenomenon of the steam turbine and achieved normal grid connection power generation.
作者 韩杰海 徐甲庆 HAN Jiehai;XU Jiaqing(Hanbao Company Energy Center of Handan Iron and Steel Group, Handan, Hebei 056015, China)
出处 《冶金动力》 2019年第7期55-56,共2页 Metallurgical Power
关键词 汽轮机 原因分析 转速飞升 steam turbine cause analysis rapid rise of rotation speed
  • 相关文献

参考文献1

二级参考文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部