期刊文献+

自然循环装置试验初始条件实现方法研究

Realization Method of Initial Test Condition of Natural Circulation Test Facility
在线阅读 下载PDF
导出
摘要 针对全厂断电事故中主回路自然循环现象的试验模拟问题,基于自然循环试验装置及其运行参数,建立了数值分析模型,采用功率积分、参数拟合等方式对自然循环试验初始条件的实现过程进行了研究。结果表明:采用功率积分或参数拟合等运行方式均可在自然循环试验装置中实现试验初始条件及状态;与参数拟合相比,积分功率法中系统参数的瞬态效应更为明显,其对应的主回路平均温度、系统压力和循环流量更高。 Aiming at the experimental simulation of natural circulation phenomenon occurring in reactor coolant system during blackout accident,based on the natural circulation test facility (NCTF) and its operating parameters,a numerical model for analysis is established.The realization process of initial conditions for natural circulation test is studied by means of power integration method (PIM) and parameters fitting method (PFM). The results show that the initial conditions and state of the natural circulation test can be achieved in NCTF by PIM or PFM.Besides,compared with PFM,the transient effect of system parameters in PIM is more obvious, and the corresponding average temperature of main loop,system pressure and circulation flow rate are higher.
作者 刘宇生 阿不都赛米·亚库甫 庄少欣 许超 安婕铷 王昆鹏 Liu Yusheng;Abudusaimi Yakufu;Zhuang Shaoxin;Xu Chao;An Jieru;Wang Kunpeng(Nuclear and Radiation Safety Center,MEE,Beijing 100082,China;National Defense Key Laboratoryof Nuclear Safety and Simulation Technology,Harbin Engineering University,Harbin 150001,China)
出处 《核安全》 2019年第3期56-61,共6页 Nuclear Safety
基金 国家科技重大专项资助项目,核动力厂安全分析用计算机软件评估基准题及共享平台开发,项目编号:2019ZX06005001
关键词 自然循环 初始条件 热工水力 整体效应 试验验证 natural circulation initial condition thermo hydraulic integral effect test verification
  • 相关文献

参考文献8

二级参考文献17

  • 1卢冬华,白雪松,黄彦平,刘叶.扁矩形通道CHF试验研究及其CHF关系式的分析评估[J].核科学与工程,2004,24(3):242-248. 被引量:8
  • 2Westinghouse Electric Company. LOFTRAN code description and user' s manual, WCAP 7878 [R]. USA.. Westinghouse Electric Company, 2005.
  • 3NRC. Final safety evaluation report related to certification of the AP1000 standard design (NUREG-1973) [R/OL]. USA: NRC, 2004 [2010-07-08]. http: //www. nrc. gov/reading- rm/doc-collections/nuregs/staff/sr1973/chapter21. pdf.
  • 4LOUIS M S, YUTAKA K. Implication of the ROSA/AP600 high and intermediate pressure test results[J]. Nuclear Technology, 1997, 199 (3) : 217-233.
  • 5REYES N J, LAWRENCE H. Scaling analysis for the OSU AP600 test facility (APEX)[J]. Nuclear Engineering and Design, 1998, 186 (12) : 53-109.
  • 6WRIGHT R F. Simulated AP1000 response to design basis small-break LOCA events in APEX- 1000 test facility [J]. Nuclear Engineering and Technology, 2007, 39(4): 287-298.
  • 7NRC. Final safety evaluation report related to certification of the AP600 standard design, NUREG-1512[R]. Washington D. C.: NRC, 1998.
  • 8袁添鸿,于雷,王川.全厂断电事故下AP1000非能动余热排出系统分析[J].原子能科学技术,2010,44(B09):248-252. 被引量:20
  • 9聂昌举.AP1000全厂断电事故分析[J].核电工程与技术,2011(3):16-20. 被引量:8
  • 10陈炼,常华健,李玉全,叶子申,秦本科.ACME整体性能试验设施工作压力选取方案分析[J].原子能科学技术,2011,45(10):1215-1220. 被引量:16

共引文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部