期刊文献+

A follow-up analysis of cardiac function and complications in pediatric patients with permanent epicardial pacing

A follow-up analysis of cardiac function and complications in pediatric patients with permanent epicardial pacing
原文传递
导出
摘要 Background Nowadays, the number of pediatric patients receiving permanent pacemaker implantations is increasing. However, there is very little relevant, long-term follow-up analysis carried out in China. Methods Clinical information from pediatric patients who underwent epicardial permanent pacemaker implantation from January 1, 2005 to December 31, 2017 in Guangdong Provincial People's Hospital was collected. Eligible patients received 12-lead electrocardiograms and echocardiography preoperatively and postoperatively, as well as programming control during their follow-up. Meanwhile, complications were treated and analyzed. Results A total of98 pediatric patients with permanent epicardial pacing were included in the study, including 60 males and 38 females. The age of patients who underwent surgery for the first time ranged from 8 days to 14 years old( the median age of these patients was 3 years old). The weight of these patients ranged from 2.7 kg to 52 kg(the median weight of these patients was 12 kg). Three patients died while they were getting treatment. The follow-up was carried out on eighty-seven out of ninety-five patients(91.6%) and lasted 5 months to 13 years( average 3.79±3.06 years). One patient with single-chamber right ventricular pacing was found to have cardiac insufficiency in the second year after operation. There were 6 patients with cardiac insufficiency whose ejection fractions were less than 55%. All these patients had a single-chamber left ventricular pacing implant or double-chamber right atrial left ventricular pacing implant. Paired T-test was used to compare the preoperative LVEF with the last echocardiographic LVEF(45%±7% vs.67%±7%, P < 0.05),which indicated statistical differences. Conclusion A permanent epicardial pacemaker is safe and effective and reasonable pacing mode can protect cardiac function.[S Chin J Cardiol 2019;20(1):10-14] Background Nowadays, the number of pediatric patients receiving permanent pacemaker implantations is increasing. However, there is very little relevant, long-term follow-up analysis carried out in China. Methods Clinical information from pediatric patients who underwent epicardial permanent pacemaker implantation from January 1, 2005 to December 31, 2017 in Guangdong Provincial People's Hospital was collected. Eligible patients received 12-lead electrocardiograms and echocardiography preoperatively and postoperatively, as well as programming control during their follow-up. Meanwhile, complications were treated and analyzed. Results A total of98 pediatric patients with permanent epicardial pacing were included in the study, including 60 males and 38 females. The age of patients who underwent surgery for the first time ranged from 8 days to 14 years old( the median age of these patients was 3 years old). The weight of these patients ranged from 2.7 kg to 52 kg(the median weight of these patients was 12 kg). Three patients died while they were getting treatment. The follow-up was carried out on eighty-seven out of ninety-five patients(91.6%) and lasted 5 months to 13 years( average 3.79±3.06 years). One patient with single-chamber right ventricular pacing was found to have cardiac insufficiency in the second year after operation. There were 6 patients with cardiac insufficiency whose ejection fractions were less than 55%. All these patients had a single-chamber left ventricular pacing implant or double-chamber right atrial left ventricular pacing implant. Paired T-test was used to compare the preoperative LVEF with the last echocardiographic LVEF(45%±7% vs.67%±7%, P < 0.05),which indicated statistical differences. Conclusion A permanent epicardial pacemaker is safe and effective and reasonable pacing mode can protect cardiac function.[S Chin J Cardiol 2019;20(1):10-14]
作者 ZHONG Cui-yao LIU Tian ZENG Shao-ying XIE Yu-mei ZHANG Zhi-wei 钟翠瑶;刘甜;曾少颖;谢育梅;张智伟(Department of Pediatric Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital)
出处 《South China Journal of Cardiology》 CAS 2019年第1期10-14,24,共6页 岭南心血管病杂志(英文版)
基金 supported by National Key R&D Program of China(No.2016YFC1100300)
关键词 PEDIATRIC patients PERMANENT EPICARDIAL PACING FOLLOW-UP COMPLICATIONS pediatric patients permanent epicardial pacing follow-up complications
  • 相关文献

参考文献4

二级参考文献195

  • 1Rasmussen K.Chronic sinus node disease:natural course and indications for pacing.Eur Heart J,1981,2:455-459.
  • 2Linde-edelstam C,Nordlander R,Pehrsson SK,et al.A doubleblind study of submaximal exercise tolerance and variation in paced rate in atrial synchronous compared to activity sensor modulated ventricular pacing.PACE,1992,15:905-915.
  • 3Gammage M,Schofield S,Rankin I,et al.Benefit of single setting rate responsive ventricular pacing compared with fixed rate demand pacing in elderly patients.PACE,1991,14:174-180.
  • 4Kay R,Estioko MWI.Primary sick sinus syndrome as an indication for chronic pacemaker therapy in young adults:incidence,clinical features,and long-term evaluation.Am Heart J,1982,103:338-342.
  • 5Shaw DB,Holman RR,Gowers JI.Survival in sinoatrial disorder (sick-sinus syndrome).Br Med J,1980,280:139-141.
  • 6Rubenstein JJ,Schulman CL,Yurchak PM,et al.Clinical spectrum of the sick sinus syndrome.Circulation,1972,46:5-13.
  • 7Fisher JD.Role of electrophysiologic testing in the diagnosis and treatment of patients with known and suspected bradycardias and tachycardias.Prog Cardiovasc Dis,1981,24:25-90.
  • 8Reiffel JA,Kuehnert MJ.Electrophysiological testing of sinus node function:diagnostic and prognostic application-including updated information from sinus node electrograms.PACE,1994,17:349-365.
  • 9Friedberg CK,Donoso E,Stein WG.Nonsurgical acquired heart block.Ann N Y Acad Sci,1964,111:835-847.
  • 10Johansson BW.Complete heart block.A clinical,hemodynamic and pharmacological study in patients with and without an artificial pacemaker.Acta Med Scand Suppl,1966,451:1-127.

共引文献99