期刊文献+

石墨消解-电感耦合等离子体质谱(ICP-MS)法测定铜精矿中汞的含量 被引量:12

Determination of Mercury Content in Copper Concentrate by ICP-MS with Graphite Digestion
在线阅读 下载PDF
导出
摘要 称取0.2g样品于50mL样品管中,以5mL硝酸-盐酸(1∶1)混合溶液为溶剂,采用石墨消解仪对样品进行前处理。以159 Tb作内标元素补偿基体效应,用电感耦合等离子体质谱(ICP-MS)法对铜精矿中的202 Hg进行测定。结果显示,在0~50μg/L的浓度范围内,校准曲线线性相关系数在0.999 9以上,方法检出限0.019μg/L。对铜精矿标准样品的检测结果与标准值相符。铜精矿中汞的浓度在0.94~15.06μg/g时,与直接测汞仪检测结果对比基本一致。 Weigh 0.2 g sample in 50 mL sample tube,add 5 mL nitric acid- hydrochloric acid(volume ratio 1 ∶1 )mixed solution as solvent and pretreat samples by graphite digestion.Using ^159 Tb as internal standard element to compensate the matrix effect,^202 Hg in copper concentrate was detected by ICP-MS.The results showed that the linear correlation coefficient of the calibration curve is more than 0.999 9 in the concentration range of 0-50 μg/L,the detection limit of method was 0.019 μg/L.The test results of copper concentrate standard samples are in conformity with the standard value.When the concentration of mercury in copper concentrate is in the range of 0.94-15.06 μg/g, the results are basically the same with the direct mercury analyzer.
作者 陈冉冉 马成骋 张晓天 李先和 万双 CHEN Ranran;MA Chengcheng;ZHANG Xiaotian;LI Xianhe;WAN Shuang(Yanggu Xiangguang Copper Co. Ltd.,Liaocheng,Shandong 252327,China;Qingdao No.58 Middle School,Qingdao,Shandong 266000,China)
出处 《中国无机分析化学》 CAS 2019年第2期20-23,共4页 Chinese Journal of Inorganic Analytical Chemistry
关键词 铜精矿 石墨消解 ICP-MS copper concentrate mercury graphite digestion ICP-MS