摘要
本文介绍了配电网高可靠性接线的3种模式,并对配电网中高可靠性接线模式1、2、3的负荷转移能力、经济性及可靠性进行了综合对比分析。结果表明模式1、2负荷转移能力比较强,模式3比较弱,3种接线模式与传统模式相比更具经济性和可靠性,极大地提高了系统平均供电率。
This paper introduces three modes of high reliability connection in distribution network, and makes a comprehensive comparative analysis of load transfer ability, economy and reliability of high reliability connection modes 1, 2 and 3 in distribution network. The results show that mode 1 and 2 have stronger load transfer ability, mode III is weaker, and the three modes are different from each other. The traditional mode is more economical and reliable, which greatly improves the average power supply rate of the system.
出处
《电力系统装备》
2018年第12期34-35,共2页
Electric Power System Equipment
关键词
配电网开关站
高可靠性
接线模式
比较
distribution network switching station
high reliability
connection mode
comparison