期刊文献+

基于IPPG非接触式生理参数测量算法的研究 被引量:14

Study on the measurement algorithm of contactless physiological parameter based on imaging photoplenthysmography
暂未订购
导出
摘要 介绍了基于成像式光电容积描记技术(imaging photoplethysmography,IPPG)的非接触式人体生理参数测量算法的研究工作。在自主研发的IPPG非接触生理参数测量仪中运用IPPG的新原理。运用视频图像处理的新方法,基于视频信号检测经过人体组织和血液吸收后的反射光强不同,从得到的脉搏波中计算出心率、呼吸频率及血氧饱和度。实现了人体生理参数无创连续非接触测量的新技术。经过实验验证与对比分析,本系统取得了较好的测量效果。在未来家庭健康医疗发展的场景下,具有很大的应用价值。 To introduce the research work of non-contact human physiological parameter measurement algorithm based on imaging photoplethys mography(IPPG).The new principle of IPPG was applied in the self-developed IPPG non-contact physiological parameter measuring instrument.By using a new method of video image processing,the heart rate,respiration rate,and blood oxygen saturation were calculated from the pulse waves based on video signal detection.The new technology of noninvasive,continuous,and noncontact measurement of human physiological parameters was achieved.The experimental verification and comparative analysis prove that the system has exhibited better measurement results.It has great development and application in the future development of family health care.
作者 荣猛 范强 李凯扬 RONG Meng;FAN Qiang;LI Kaiyang(School of Physics and Technology,Wuhan University,Wuhan 430072,China)
出处 《生物医学工程研究》 2018年第1期27-31,35,共6页 Journal Of Biomedical Engineering Research
基金 国家重大科学仪器设备开发专项资助项目(2012YQ160203)
关键词 成像式光电容积描记技术 非接触 心率 呼吸频率 血氧饱和度 Imaging photoplethysmography Non-contact Heart rate Respiratory rate Blood oxygen saturation
  • 相关文献

参考文献3

二级参考文献23

  • 1Droitcour AD,Boric-Lubecke O,Libecke VM,et al.0.25μm CMOS and BiCMOS Single-chip Direct-conversion Doppler Radars for Remote Sensing of Vital Signs[C].2002 ISSCC Digest.2002 (1):348
  • 2Alien J. Photoplethysmography and its application in clinical physio- logical measure -ment [ J ]. Physiological Measurement,2007 : 1 - 39.
  • 3罗志昌,张松,杨益民,李雯旭.光电容积脉搏波描记法原理及其在临床上的应用[J].世界医疗器械,2000,6(9):41-47.
  • 4Verkruysse W, Svaasand L O, Nelson J S. Remote plethysmograph- ic imaging using ambient light [J]. OpL Express, 2008, 16(26) : 21434 - 21445.
  • 5Wieringa F P, Mastik F, and Van der Steen A F W. Contaetless multiple wavelength photoplethysmographie imaging: a first step to- ward "spo2 camera" technology[ J]. Annals of biomedical engineer- ing, 2005,33(8) :1034 - 1041.
  • 6Hu Sijung, Zheng Jia, Chouliaras Vassilios, Summers Ron. Feasi- bility of imaging Photo - plethysmography [ C ]. BioMedical Engi- neering and Informatics, 2008,2 : 72 - 75.
  • 7Poh M Z, McDuff D J, Picard R W, Advancements in noncontaet, multiparameter physiological measurements using a webcarn [ J ] , IEEE Trans. Biomed. Eng, 2011, 58(1) :0018 -9294.
  • 8Lewandowska M, Ruminski J, Nowak J. Measuring pulse rate with a webcam - A non - contact method for evaluating cardiac activity [ C ]. Proceedings of the Federated Conference on Computer Sci- ence and Information Systems, Szczeein,2011:405 - 410.
  • 9Tsouri G R, Kyal S, Dianat S, Mestha L K. Constrained inde- pendent component analysis approach to nonobstrusive pulse rate measurements [ J ]. Journal of Biomedical Optics, 2012, 17 (7) :077011.
  • 10Viola, Paul A and Jones, Michael J. Rapid Object Detection using a Boosted Cascade of Simple Features [ C]. 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, 2001,1:511 -518.